OPERATION
2
2.4.3
Switch output forcible ON mode
2.4.4
Zero point adjustment
Note: Always adjust 0 point without flow.
Note: If fluid flows during zero adjustment setting, “E 02” is indicated.
Note: The offset value is different to display it by the operation processing value from an actual
flowing quantity value.
Forcible output setting display
To Instantaneous flow rate display
Press once
2
1
1 2
0 point adjustment setting display.
To Instantaneous flow rate display
Press once
(
determination
)
Press once
Press simultaneously
(Adjusted value reading)
Adjustment value display
(CH1 output ON)
Being
held down
Being
held down
Being
held down
(CH2 output ON)
(CH1 and CH2 output ON)
Discontinue