29
−
OPERATION
2
●
How to take set point by key operation
・
1-point input : The set point takes the flow rate when press key for 2 sec.
・
2-point input : The upper limit takes the flow rate when press key for 2 sec.
The lower limit takes the flow rate when press key for 2 sec.
・
After taking, the set point is displayed.
●
How to take set point by external input
・
1 point input : The set point takes the flow rate when external input is turned on (keep approx. 40msec.).
・
2 points input : The set point takes the flow rate when external input is turned on (keep approx. 40msec.).
The big and small relations between latest two points are compared, upper limit and lower limit are distin-
guished automatically.
(
Example
)
・
After taking, the set point is displayed. Also the pulse is output from CH1 for the taking confirmation.
・
The set point value is cleared if power is turned OFF.
Input point
(
mL/min
)
Upper limit
(
mL/min
)
Lower limit
(
mL/min
)
Initial value
0
0
1
st
123
0
123
2
nd
234
123
234
3
rd
45
45
234
4
th
345
45
345
5
th
456
345
456
An initial value is zero in both bound
Discontinue