![CKD ABSODEX AX9000XS-U2 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/ckd/absodex-ax9000xs-u2/absodex-ax9000xs-u2_instruction-manual_2611713018.webp)
3. CC-Link Communication Function
[SMF-2008-A]
– 3-5 –
Table 3.8. Writing command code (RWwn+2) list
Code
No.
Item/Function
Written data
Written data
designation
RWwn+5
RWwn+3
RWwn+4
0021h
Operation mode
switching
Automatic operation
number
0 (fixed)
-
0029h
Parameter setting
Lower 16 bits of parameter
set value
Upper 16 bits of parameter
set value
Parameter
number
0030h
Point table initialization
Table number initialized
0 (fixed)
-
0031h
Parameter initialization
999
0 (fixed)
-
Operation mode switching (0021h)
The mode is switched to the operation mode designated with written data.
The switchable modes and set values are as shown in the following.
Table 3.9. Switchable operation mode list
Operation mode
Written data
Set value
Automatic operation mode
1
Single block mode
2
Servo OFF mode
5
Network operation mode
7
Parameter setting (0029h)
The set value of the parameter designated with the parameter number (RWwn+5) is rewritten to
the value of written data.
Written data are integer values only.
As for a parameter with a decimal value, set a value multiplied by 100 or 10,000.
For details, refer to the “Parameter list” on page 3-6.
Point table initialization (0030h)
Point tables designated with written data are initialized.
When the written data are 999, all point tables including shared tables are initialized.
The value after initialization is as shown in the following.
Table 3.10. Point tables after initialization
Type
Instruction
Movement
unit
Movement
speed unit
A code/P code
F code
Shared table
Absolute
x 1,000 [deg.]
x 1,000 [rpm]
-
-
Table number 0 to 63
Shared table
Shared table
Shared table
0
2,000
Parameter initialization (0031h)
The set values of all parameters are initialized.
Parameter 61 (station number and baud rate setting) is not targeted.