3. CC-Link Communication Function
[SMF-2008-A]
– 3-1 –
3. CC-Link Communication Function
3.1. Communication Specifications
Table 3.1. Communication specifications
Item
Specification
Power supply
Supply 5V DC from the servo amplifier.
CC-Link version
Ver.1.10
Number of stations
occupied (station type)
2 (remote device station)
Number of remote input
points
48
Number of remote output
points
48
Remote register I/O
8 input words, 8 output words
Communication speed
10M/5M/2.5M/625k/156kbps
(Selected with a parameter setting)
Communication method
Broadcast polling
Synchronization method
Frame synchronization method
Coding method
NRZI
Transmission path type
Bus type (compliant with EIA RS-485)
Error control method
CRC (X
16
+X
12
+X
6
+1)
Connection cable
Cable compatible with CC-Link Ver. 1.10
(3-conductor twisted pair cable with shield)
Transmission format
Compliant with HDLC
Remote station number
1 to 63 (parameter setting)
Number of connected
modules
Max. 32 remote device stations, 2 stations
occupied