EC Declaration of Conformity In accordance with 768/2008/EC 

 

We CityEV Ltd. of Technopole, Kingston Crescent, Portsmouth, UK. PO2 8FA 
In accordance with the following Directives: 
 
2014/35/EU - The Low Voltage Directive 
 
2004/108/EC The Electromagnetic Compatibility Directive;  
Hereby declare that: Equipment: Earth Fault Protection Equipment - 

Safevolt

 

50 

 
Is in conformity with the applicable requirements of the following documents: 
 

Ref. No. 

 

Title 

 

 

BS EN 61000-6-1 

 

Electromagnetic compatibility (EMC). 
Generic standards. Immunity for residential, 
commercial & light-industrial environments 2007 

 
BS EN 61000-6-3 

 

Electromagnetic compatibility (EMC). 
Generic standards. Emission standard for 
residential, commercial & light-industrial 
environments 2007 

 
EN 61000-3-2 

 

Electromagnetic compatibility (EMC), 2014 

 

Part 3-2 - Limits; Limits for harmonic current emissions 

 
EN 60335-1 

 

household and similar electrical appliances. Safety, 2012 

  

part 1: general requirements 

 
BS 7671 

 

Fully compliant with section 722.411.4.1 (iv), 2018 

 

(Electric vehicle charging installations, TN systems) 

 
I hereby declare that the equipment named above is compliant with the relevant sections of the above referenced 
specifications. The unit complies with all applicable Essential Requirements of the Directives. 
 
Name: 

R Morris, CTO,  

Date: 

21st August 2020

 

 

CityEV Ltd. 2020 

 

Documents may include an extract taken from the IET Standards Code of Practice for Electric Vehicle Charging Equipment Installation 3

rd

 Edition; 

note that this is their copyright material and is acknowledged; the extract is for the illustration of the IET recommendations only, in the 

commercial interests of improving safety and compliance; the CityEV Safevolt® 50 is a commercial product with relevant CityEV trademarks and 

patent applications and has no connection with any organisation outside CityEV Ltd. and is not specifically endorsed by any other organisation. 

 

 

CityEV designs are covered by one or more patent applications. The CityEV logos are registered trademarks.  

 

Information is corect at the time of writing and will be updated in line with development is the relavant standards and regulations. 

 

CityEV Helpline:  02393 190109 

[email protected]

 

Содержание Safevolt 50

Страница 1: ...Documentation Revision 1 31 September 2020 Copyright 2020 CityEV Limited All Rights Reserved All trademarks are owned by CityEV Limited CityEV Safevolt 50 User and Installation Manual...

Страница 2: ...fety Information 3 The CityEV Safevolt 50 5 Safevolt 50 Operation 5 Positioning 7 Removing the cover 7 Connections 8 Electrical Testing 9 Precautions 9 General 9 10 Using SWA cables with Safevolt 50 1...

Страница 3: ...ED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW CITYEV NET Revision 1 31 Date September 2020 Product Part Number Safevolt 50 About Your System As soon as you open your product record the f...

Страница 4: ...tion or service work Do not remove the device cover while the power supply is connected Do not operate the device with the cover removed Do not attempt to repair or replace any part of the device In c...

Страница 5: ...le Charging Equipment There is no need to convert to TT or install an isolation transformer Safevolt 50 Operation The Safevolt 50 status indicators are shown and described below During normal operatio...

Страница 6: ...50 unit is not weather protected and intended for indoor installation only Figure 2 below shows typical single phase charge point installation using the Safevolt 50 protection unit Safevolt 50 single...

Страница 7: ...sed e g flat T E round or SWA types Ensure cables are securely secured by glands or use cable ties if necessary Electrically the unit is connected in series with the charge point supply Removing the c...

Страница 8: ...CPC is connected to the left hand lever connectors and the outgoing supply to the charge point is connected to the right hand lever connectors as shown Note Maximum cable size is 6mm2 CityEV Safevolt...

Страница 9: ...the charge point disconnected also Precautions General The Safevolt 50 unit is designed to isolate the installation PME earth from the charge point CPC in the event of a PEN conductor PME failure It i...

Страница 10: ...oint CPC including the metal case of the Safevolt unit For instance an SWA cable terminated in the charge point case and a building DB with a metallic case will cause such a connection and is not allo...

Страница 11: ...onds Earth Fault Trip Reset Automatic Connectors Screw Terminal Max 6mm2 Indicators Output On PME Earth Fault Dimensions Wall mounting 200mm W x 70mm H x 50mm D Weight 750g Environmental Operating Tem...

Страница 12: ...1 iv 2018 Electric vehicle charging installations TN systems I hereby declare that the equipment named above is compliant with the relevant sections of the above referenced specifications The unit co...

Отзывы: