Page 37
Page 37
Page 37
Page 37
Page 37
CA
CA
CA
CA
CAUSE
USE
USE
USE
USE
4A Incorrect voltage
4B Defective steam relay
4C Loose wiring
5A Defective steam timer
5B Defective steam relay
6A Defective air toggle switch
6B Defective air solenoid
6C Defective air solenoid linkage
6D Loose wiring
6E Improper air operating lever
assembly
7A Defective steam timer
7B Defective air timer
7C V belt off or loose
7D Defective air relay
REMEDY
REMEDY
REMEDY
REMEDY
REMEDY
Check voltage of electrical parts,
particularly the steam relay.
Replace if not same as machine
nameplate voltage.
Check to see if relay will operate
on rated voltage and if contacts
will carry current. If not replace
relay.
Inspect wiring, particularly on
steam relay and steam timer.
Replace any loose wires and
tighten all connections.
Check timer operation. See that
timer motor will run and that
timer switch operates properly. If
not, replace timer.
Check steam relay to see if
contacts are welded together. If so,
replace relay.
Inspect air toggle switch in push
button box. Replace if defective.
Inspect the air solenoid. Replace if
it is burned, armature does not
move freely, or if it will not operate
on rated voltage.
Inspect linkage and levers between
air solenoid and damper. Be sure
they are arranged and adjusted
according to instructions. Replace
any broken or stretched springs.
Repair or replace any defective
parts. Tighten all set screws.
Inspect machine wiring, especially
to toggle switch and air solenoid.
Replace any loose wires and
tighten any loose connections.
Refer to parts dwgs. and assemble
levers on damper shaft properly.
Pins on these levers must be
properly arranged with respect to
adjoining levers. Repair or replace
any defective parts and adjust
according to instructions. Replace
all springs and tighten all set
screws.
Check timer operation. See that
timer motor will run and that
timer switch operates properly. If
not replace timer.
Check timer operation. See that
timer motor will run and that
timer switch operates properly. If
not, replace timer.
Check to see that the V belt is on,
properly aligned and adjusted
according to instructions.
Check to see that the air relay will
operate properly on rated voltage
and the contacts carry current. If
not, replace the relay.
PROBLEM
PROBLEM
PROBLEM
PROBLEM
PROBLEM
(4) Steams with button
depressed, won’t maintain
steam cycle
(5) Steams continuously
(6) Manual air won’t come on
(7) Auto air won’t come on