Page 17
CAUSE
Door cam out of adjustment
(switch not engaged).
Defective start switch or foot
switch.
Loose or broken wire.
Defective door interlock switch.
Door interlock switch out of
adjustment.
Conveyor interlock out of adjust-
ment.
Conveyor safety switch out of
adjustment.
Conveyor safety switch out of
adjustment.
Defective Conveyor motor.
Defective relay.
Defective or broken wiring.
Defective Conveyor interlock
switch.
Interlock switch out of adjustment.
Conveyor interlock switch out of
adjustment.
Main blower motor defective.
Main blower drive belt broken or
slipping.
Blower relay defective.
Defective wiring.
Defective timer.
Loose main blower wheel.
Loose V belt drive sheave.
Belt blower shaft.
Worn blower shaft bearing.
Defective blower wheel.
Foreign object in blower wheel.
Loose exhaust blower wheel.
Bent exhaust motor shaft.
Defective exhaust blower wheel.
Foreign object in exhaust blower
wheel.
Exhaust blower motor defective.
Blower wheel loose or defective.
Defective wiring.
Defective timer.
REMEDY
Adjust according to instructions on
Page 9.
Replace switch.
Replace or repair.
Replace switch.
Adjust switch.
Adjust indicator flag on conveyor
link.
Adjust switch.
Adjust switch.
Replace motor.
Replace relay.
Repair or replace wire.
Replace switch.
Adjust switch bracket.
Adjust indicator flag on conveyor
links.
Check and replace if needed.
Check and replace if needed.
Check and replace if needed.
Inspect and repair.
Check and replace if needed.
Reset and tighten.
Reset and tighten.
Check and replace if needed.
Check and replace if needed.
Check and replace if needed.
Remove foreign object.
Reset and tighten.
Check and replace if needed.
Check and replace if needed.
Remove foreign object.
Check and replace if needed.
Tighten or replace.
Inspect and repair.
Check and replace if needed.
TROUBLE SHOOTING CHART
PROBLEM
Door will not open.
Doors open and continue to open
and close.
Door open and conveyor advance
short distance, door close and
steam cycle start.
Door open; conveyor will not
advance.
Conveyor continues to run, will not
stop.
Conveyor out of time, will not stop
at proper position.
Drying Blower will not operate.
Excessive noise during Drying
Cycle.
Excessive noise during cycle.
Excessive loss of steam & heat
around cabinet door (exhaust
blower not operating).
Содержание FINTUNMAN67
Страница 3: ...Page 3...
Страница 6: ...Page 6...
Страница 18: ...Page 18...
Страница 22: ...Page 22...
Страница 28: ...Page 28...
Страница 30: ...Page 30...
Страница 32: ...Page 32...
Страница 34: ...Page 34...
Страница 39: ...Page 39...
Страница 40: ...Page 40...
Страница 41: ...Page 41...