Configuring the Cisco SPA500S Attendant Console
Setting Up the Cisco SPA500S Attendant Console
Cisco SPA500 Series and WIP310 IP Phone Administration Guide
169
9
•
cp—call pickup (if supported by the SIP proxy server). Call pickup (cp) must
be supported by the SIP proxy server and be used with blf in the
configuration. The syntax is fnc=blf+cp.
•
sub—Use this keyword to identify the phones to be monitored). Its value and
syntax is stationName@$PROXY, where system variable $PROXY contains the
proxy server IP and port (e.g. 192.168.8.101:6060).
NOTE
Unit/key LEDs will not light without the “sub” keyword. (Not required for
speed dials.)
•
usr or ext—Use one of these keywords to identify the specific users or
extensions to be monitored. Its value and syntax is extensionNumber@$PROXY,
where system variable $PROXY contains the proxy server IP and port (e.g.
192.168.8.101:6060). (The
usr
and
ext
keywords are interchangeable.)
•
nme (optional)— Use this field with the SPA9000 to identify any alias that has
been assigned to the extension in the IP phone configuration.The nme
parameter indicates the extension name, which in this case is the same as the
station name.
•
vid (optional)— All LEDs on the Cisco SPA500S use phone extensions that they
are assigned to. By default, LEDs on the Cisco SPA500S are assigned to the
first configured extension on the connected phone. You can optionally assign
LEDs to any other phone extensions using vid=keyword. Use this field to
identify the phone extension to use with the monitored list specified by the
sub= keyword, when more than one BLF monitored list is configured on the SIP
proxy server. The possible values are 1 to 6, corresponding to each of the six
extensions available on the phone. Only use the vid= keyword in the first entry
assigned to each phone extension. Subsequent keys will use the same
extension. See
“Attendant Console Parameters” section on page 172
.