2-9
Cisco UCS C250 Server Installation and Service Guide
OL-20888-02
Chapter 2 Installing the Server
Initial Server Setup
Initial Server Setup
This section contains the following topics:
•
Connecting and Powering On the Server (Standalone Mode), page 2-9
•
NIC Modes and NIC Redundancy Settings, page 2-12
Connecting and Powering On the Server (Standalone Mode)
Note
This section describes how to power on the server, assign an IP address, and connect to server
management when using the server
in standalone mode
. To use the server in UCS integration, specific
cabling and settings are required. See
Installation for Cisco UCS Integration, page D-1
.
Note
The server is shipped with a default NIC mode called
Shared LOM
, default NIC redundancy is
active-active, and DHCP is enabled. Shared LOM mode enables the two 1Gb Ethernet ports to access
the Cisco Integrated Management Interface (CIMC). If you want to use the 10/100 management ports or
a Cisco network adapter card port to access the CIMC, you must first connect to the server and change
the NIC mode as described in
Step 3
of the following procedure. In that step, you can also change the
NIC redundancy and set static IP settings.
Use the following procedure to perform initial setup of the server.
Step 1
Attach a supplied power cord to each power supply in your server, and then attach the power cord to a
grounded AC power outlet. See the
“Power Specifications” section on page A-2
for power specifications.
Wait for approximately two minutes to let the server boot in standby power during the first bootup.
Note
Depending on how much memory is installed in the server, bootup might take two minutes or more
because of the memory verification operation during bootup. Servers with the full 384 GB of memory
might take up to four minutes to boot.
You can verify power status by looking at the Power Status LED (see
Figure 1-1 on page 1-1
):
•
Off—The server is not receiving power. Check the power cord connections and the power source of
the facility.
•
Amber—The server is in standby power mode. Power is supplied only to the CIMC and some
motherboard functions.
•
Solid green—The server is in main power mode. Power is supplied to all server components.
Note
During bootup, the server beeps once for each USB device that is attached to the server. Even if there
are no external USB devices attached, there is a short beep for each virtual USB device such as a virtual
floppy drive, CD/DVD drive, keyboard, or mouse. A beep is also emitted if a USB device is hot-plugged
or hot-unplugged during BIOS power-on self test (POST), or while you are accessing the BIOS Setup
utility or the EFI shell.
Step 2
Use the supplied KVM cable to connect a keyboard and VGA monitor to the console connector on the
front panel (see
Figure 1-1 on page 1-1
).
Содержание UCS C250
Страница 6: ...Contents vi Cisco UCS C250 Server Installation and Service Guide OL 20888 02 ...
Страница 12: ...xii Cisco UCS C250 Server Installation and Service Guide OL 20888 02 Preface ...
Страница 14: ...xiv Cisco UCS C250 Server Installation and Service Guide OL 20888 02 Preface ...
Страница 18: ...1 4 Cisco UCS C250 Server Installation and Service Guide OL 20888 02 Chapter 1 Overview ...