5. Enable the management port with the
no shutdown
command. You can now telnet to your Topspin
360, or enter the IP address of your Topspin 360 in a Web browser to launch Chassis Manager.
Example
6. Save the configuration to preserve it between reboots.
Example
For the VFrame Evaluation Test Plan, continue to
Step c
of
“Hardware Configuration Steps” on page 14
in the
“VFrame Evaluation Test Plan”
.
Connect InfiniBand Hosts
This section describes a brief overview for connecting your InfiniBand hosts. For more detailed
instructions, please see the
Host Channel Adapter Installation Guide
, which is included with your
HCA(s).
Topspin-360(config-if-mgmt-ethernet)#
no shutdown
Topspin-360(config-if-mgmt-ethernet)#
exit
Topspin-360(config)#
exit
Topspin-360#
copy running-config startup-config