Installing and Cabling the Displays
© 2015 Cisco Systems, Inc. All rights reserved.
Page 83
8
Level the displays and and make the left and right displays vertically level with the center display. Use
the left and right levelers to create an even gap between the left and center, and center and right,
displays. Use a 6mm T-handle hex driver to turn the leveler from below (it has a socket in the end of the
threaded stud). Tighten the lock nut on the levelers after you complete leveling.
Leveler
Leveling
bracket
View from back - use a 6mm T-handle
hex driver from below to adjust levelers