Advanced Options for Voice Services
Configuring Dial Plans
Administration Guide
146
9
Interdigit Short Timer (Complete Entry Timer)
You can think of this timer as the “complete entry” timer. This timer measures the
interval between dialed digits. It applies when the dialed digits match at least one
digit sequence in the dial plan. Unless the user enters another digit within the
specified number of seconds, the entry is evaluated. If it is valid, the call proceeds.
If it is invalid, the call is rejected. Default setting: 3 seconds
Syntax for the Interdigit Short Timer
SYNTAX 1:
S
:s,
(
dial plan
)
Use this syntax to apply the new setting to the entire dial plan within the
parentheses.
SYNTAX 2:
sequence
Ss
Use this syntax to apply the new setting to a particular dialing sequence.
s: The number of seconds; if no number is entered after
S
, the default timer of 5
seconds applies.
Examples for the Interdigit Short Timer
Set the timer for the entire dial plan.
S:6
,(9,8<:1408>[2-9]xxxxxx | 9,8,1[2-9]xxxxxxxxx | 9,8,011xx. | 9,8,xx.|[1-8]xx)
S:6,
While entering a number with the phone off hook, a user can pause for up to
15 seconds between digits before the Interdigit Short Timer expires.
Set an instant timer for a particular sequence within the dial plan.
(9,8<:1408>[2-9]xxxxxx |
9,8,1[2-9]xxxxxxxxxS0
| 9,8,011xx. | 9,8,xx.|[1-8]xx)
9,8,1[2-9]xxxxxxxxxS0
With the timer set to 0, the call is transmitted
automatically when the user dials the final digit in the sequence.
Resetting the Control Timers
You can use the following procedure to reset the default timer settings for all calls.
NOTE
To edit a timer setting only for a particular digit sequence or type of call, you can
edit the dial plan. See
Digit Sequences, page 139
.