Cisco MDS 9100 Series Hardware Installation Guide
OL-21514-01
Chapter 2 Installing the Cisco MDS 9100 Series
Removing and Installing Components
Cisco MDS 9134 Switch has two hot-swappable power supplies and two hot-swappable fan modules.
The Cisco MDS 9124 Switch is shipped with one field-replaceable power supply and three fixed fans.
The Cisco MDS 9134 switch and the Cisco MDS 9124 switch support the new DC power supply.
This section provides the following information:
•
Removing and Installing AC Power Supplies, page 2-29
•
Removing and Installing DC Power Supplies, page 2-30
•
Removing and Installing Fan Modules, page 2-32
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
Caution
During this procedure, wear grounding wrist straps to avoid ESD damage to the switch.
Note
Except for the Cisco MDS 9124 switch, all the the other Cisco MDS 9100 Series switches are supported
for operation with both power supplies and both fan modules installed, and with all fans working.
With two power supplies installed, if one power supply fails, the system can continue to function
normally on a single healthy power supply. However, the failed power supply should be replaced as soon
as possible to provide redundancy.
The fan modules are required to ensure proper cooling of the switches. See
Figure 2-20
,
Figure 2-21
,
Figure 2-22
, and
Figure 2-23
.
Figure 2-20
Rear View of the Cisco MDS 9148 Switch
DS - C48 - 300A
C
100 - 240V
AC
4 - 2 A
50 - 60 Hz
INPUT
OK
OUTPUT
OK
Power
module
Fan
module
Fan
module
DS - C48 - 300A
C
100 - 240V
AC
4 - 2 A
50 - 60 Hz
INPUT
OK
OUTPUT
OK
Power
module