S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
2-13
Cisco MDS 9100 Series Hardware Installation Guide
OL-21514-01
Chapter 2 Installing the Cisco MDS 9100 Series
Installing the Switch in a Cabinet with Insufficient Front Clearance
Installing Front Rack-Mount Brackets for Cabinets with 26 Inches or Greater of
Rail Spacings
The front rack-mount brackets for the Cisco MDS 9100 Series switch must be installed onto the switch
prior to installing the switch into the cabinet. Follow these steps for cabinets with front-mounting rail to
rear-mounting rail spacings greater or equal to 26 inches.
Step 1
Install the front rack-mount brackets as follows:
a.
Position one of the front rack-mount brackets against the side of the switch and align the screw holes
as shown in
Figure 2-8
. Then attach the bracket to the switch with the three M4 screws originally
provided with the bracket.
b.
Repeat with the other front-rack mount bracket on the other side of the switch.
Step 2
Install the C brackets as follows:
Note
Two C brackets are shipped preinstalled on the switch, using three M3 screws per bracket. This
installation step is only necessary if the C brackets were removed.
a.
Position one of the C brackets against the side of the switch and align the screw holes as shown in
Figure 2-8
. Then attach the bracket to the switch with the three M3 screws originally provided with
the bracket.
b.
Repeat with the other C bracket on the other side of the switch.
Figure 2-8
Front Rack-Mount Brackets and C Brackets Installed on the Cisco MDS 9100 Series
1
Front rack-mount bracket
2
C bracket
96616
1