SPA9000 Field Reference
Voice tab
SPA9000 Voice System Administration Guide
238
B
Time Zone
Selects the number of hours to add to GMT to generate the
local time for caller ID generation. Choices are GMT-12:00,
GMT-11:00,…, GMT, GMT+01:00, GMT+02:00, …, GMT+13:00.
Default:
GMT-08:00
FXS Port Impedance
Sets the electrical impedance of the FXS port. Choices are
600
,
900
,
600+2.16uF
,
900+2.16uF
,
270+750||150nF
,
220+850||120nF
,
220+820||115nF
, or
200+600||100nF
.
Default:
600
Daylight Saving Time
Rule
Enter the rule for calculating daylight saving time; it should
include the start, end, and save values. This rule is comprised
of three fields. Each field is separated by ; (a semicolon) as
shown below. Optional values inside [ ] (the brackets) are
assumed to be 0 if they are not specified. Midnight is
represented by 0:0:0 of the given date.
SYNTAX:
start = <start-time>; end=<end-
time>; save = <save-time>
The <start-time> and <end-time> values specify the start
and end dates and times of daylight saving time. Each value is
in this format: <month> /<day> / <weekday>[/HH:[mm[:ss]]]