Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration
Initial System Configuration
SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-02
5-15
Type “
any
” and press
Enter
to include any IP address in the ACL.
Note that there is no default for this parameter.
Enter IP address or the word ‘any’ to denote any IP address:
Step 6
If you entered a specific IP address, enter the wildcard bits to define a range of IP
addresses and press
Enter
. (See
Entry Formats
(on page
5-13
).)
To define an individual IP address, type
0.0.0.0
and press
Enter
.
There is no default for this parameter.
Enter wildcard bits:
Step 7
The maximum number of entries in an ACL is 20.
If the “any” option was used, no other IP addresses may be added to the list.
•
To add more entries, type
y
and press
Enter
Would you like to add another entry to this list? [no]:
y
Enter up to 20 entries as described in step 5 and step 6.
•
When all entries have been added, press
Enter
Would you like to add another entry to this list? [no]:
Step 8
When all entries are added to one list, you are asked whether you would like to create
another ACL. You may define up to 99 ACLs.
•
To create another ACL, type
y
and press
Enter
Would you like to configure another list? [no]:
y
Enter up to 20 IP addresses in this new ACL, as described in step 5 and step 6.
•
When all ACLs have been created, press
Enter.
Would you like to configure another list? [no]:
You are now prompted to assign the desired ACLs to restrict IP and Telnet access.
Step 9
Restrict IP access to the
SCE 2000
by assigning the appropriate ACL.
Type the number of the ACL to be assigned to IP access and press
Enter.
To accept the default ACL, press
Enter.
Enter IP access-class [0]:
Step 10
Restrict Telnet access to the
SCE 2000
by assigning the appropriate ACL.
Type the number of the ACL to be assigned to the Telnet interface and press
Enter.
To accept the default ACL, press
Enter.
Enter Telnet access-class [0]:
2