C H A P T E R
6
Installing the Supervisor in the Cisco cBR
Chassis
This section provides information on installing the Supervisor.
Check if your hardware might have a supervisor card. For supervisor cards that are shipped as a spare module,
the supervisor card bootflash would be empty. Ensure that you manually copy the image on the bootflash to
avoid issues while booting.
•
Installing the Supervisor 160G, on page 89
•
Installing the Supervisor 250G, on page 109
Installing the Supervisor 160G
Installing the Supervisor PIC in the Cisco cBR Chassis
Perform this procedure to install the following PICs:
• Supervisor PIC
• Blank PIC for the Supervisor
Before you begin
If you are adding a new Supervisor PIC or upgrading the existing Supervisor PICs, ensure that the power
modules installed in the chassis are adequate to support the Supervisor PICs.
Warning
• Attach an ESD-preventive wrist strap to your wrist and connect the other end to the grounding lug
connected to the chassis.
• Be aware of the weight and size of the equipment. Handle it with care.
Restrictions
• If you are using a single Supervisor, you must install the Supervisor PIC in the slot corresponding to the
Supervisor Card.
Cisco Converged Broadband Routers Hardware Installation Guide
89