Table 45: Upstream PHY Module Troubleshooting
Solution
Possible Cause
Problem
The upstream PHY module should
be re-installed to ensure that it is
properly seated.
The upstream PHY module is not
seated properly.
The PowerGood value 0 in the
output of the
show cable card
slot/subslot us-phy display |
include PowerGood
command
shows that the upstream PHY
module in the line card is not
powered up.
Refer to the
for
more information on service.
The upstream PHY module is
damaged.
Reboot the interface card. If the
STATUS LED does not illuminate,
replace the line card.
The interface card is not booted.
The STATUS LED is not
illuminated.
Replace the interface card.
The interface card needs to be
replaced.
The REPLACE LED is illuminated
in white color.
Cisco Converged Broadband Routers Hardware Installation Guide
258
Troubleshooting the Cisco cBR
Troubleshooting the Interface Cards in Cisco cBR Chassis