background image

   

4-6

Catalyst 4500 E-Series Switches Installation Guide

OL-13972-01

Chapter 4      Removing and Replacing FRUs

Removing and Replacing the Power Supply

Figure 4-8

Handling an AC-Input Power Supply

Step 6

Pull the power supply out of the bay and set it aside.

Warning

Blank faceplates and cover panels serve three important functions: they prevent exposure to 
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) 
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not 
operate the system unless all cards, faceplates, front covers, and rear covers are in place. 

Statement 1029

Step 7

If the power supply bay is to remain empty, install a blank power supply filler plate over the opening. 
Secure the filler plate with the two mounting screws and tighten them with a screwdriver. 

Installing an AC-Input Power Supply

Warning

The plug-socket combination must be accessible at all times, because it serves as the main 
disconnecting device. 

Statement 1019

Follow these steps to install an AC-input power supply:

Step 1

Make sure that the power supply you are installing is not plugged in to a power outlet and that the power 
cord is not connected to the power supply.

Step 2

Remove the two Phillips-head screws from the power supply filler plate (if a filler plate is present).

Step 3

Remove the power supply filler plate (if one is present) and set it aside.

Caution

Use both hands to grasp a power supply.

Step 4

Grasp the power supply handle with one hand. Place your other hand underneath to support the bottom 
of the power supply, as shown earlier in 

Figure 4-8

.

Step 5

Slide the power supply all the way into the power supply bay.

79141

Содержание Catalyst 4500e Series

Страница 1: ...o Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Catalyst 4500 E Series Switches Installation Guide November 2007 Text Part Number OL 13972 01 ...

Страница 2: ...try to correct the interference by using one or more of the following measures Turn the television or radio antenna until the interference stops Move the equipment to one side or the other of the television or radio Move the equipment farther away from the television or radio Plug the equipment into an outlet that is on a different circuit from the television or radio That is make certain the equi...

Страница 3: ...sor Engine Redundancy 1 8 Catalyst 4507R E Switch Features 1 9 Catalyst 4510R E Switch Features 1 13 Supervisor Engines 1 16 LEDs 1 22 Gigabit Ethernet Uplink Ports 1 22 10 Gigabit Ethernet Uplink Ports 1 23 SFP Ports 1 23 10 100BASE T Management Port 1 23 CONSOLE Port 1 23 RESET Button 1 24 Compact Flash Slot 1 24 Fan Assembly 1 24 Power Supplies 1 25 Power Supply LEDs 1 28 Power Supply Fan 1 28 ...

Страница 4: ...a Rack 3 1 Checking the Shipping Container Contents 3 1 Rack Mounting the Switch 3 2 Required Installation Tools 3 2 Rack Mounting Catalyst 4500 E series Switches 3 3 System Ground Connection Guidelines 3 5 Parts and Required Tools 3 6 Connecting System Ground and Power 3 6 C H A P T E R 4 Removing and Replacing FRUs 4 1 Removing and Replacing the Power Supply 4 2 Required Tools 4 4 Removing an AC...

Страница 5: ...LI Commands 5 5 Power Supply Mixing 5 6 Troubleshooting the Fan Assembly 5 6 System Messages and Fan Problems 5 7 Useful CLI Commands 5 7 Troubleshooting Backplane Modules 5 7 Troubleshooting Switching Modules 5 8 System Messages and Switching Modules 5 9 Useful CLI Commands 5 9 Troubleshooting Supervisor Engines 5 10 System Messages and Supervisor Engines 5 10 Useful CLI Commands 5 12 Standby Sup...

Страница 6: ... E N D I X C Initial Configuration for the Switch C 1 Connecting to the Switch C 2 Starting the Terminal Emulation Software C 2 Connecting to a Power Source C 2 Entering the Initial Configuration Information C 3 IP Settings C 3 Performing the Initial Configuration C 3 A P P E N D I X D Module Overview and Specifications D 1 Catalyst 4500 Series Switches D 1 Catalyst 4500 E Series Switches D 1 Supe...

Страница 7: ... al yst4500 E ser i esswi t ches Chapt er2 Pr epar i ng f or I nst al l at i on Descr i beshow t opr epar eyoursi t ef ort hei nst al l at i onoft he swi t ch Chapt er3 I nst al l i ng t heSwi t ch i n aRack Descr i beshow t o i nst al lt heCat al yst4500 E ser i es swi t ches Chapt er4 Rem ovi ng and Repl aci ng FRUs Descr i beshow t or em oveandr epl acef i el d r epl aceabl euni t s FRUs Chapt ...

Страница 8: ...oftware version Command references are at http www cisco com en US products hw switches ps4324 prod_command_reference_list html The system message guide appropriate to your software version System message guides are at http www cisco com en US products hw switches ps4324 products_system_message_guides_list html There are a number of installation notes and technical tips available for this switch T...

Страница 9: ...ouped i n br acket sand separ at ed by ver t i calbar s st r i ng A nonquot ed setofchar act er s Do notusequot at i on m ar ksar ound t he st r i ng becauset hest r i ng wi l li ncl udet hequot at i on m ar ks screen f ont Ter m i nalsessi onsand i nf or m at i on t hatt hesyst em di spl aysar ei n screen f ont boldface screen f ont I nf or m at i on t hatyou m ustent eri sshown i n boldface scre...

Страница 10: ...n kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertisse...

Страница 11: ...situação que poderá ser causadora de lesões corporais Antes de iniciar a utilização de qualquer equipamento tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acidentes Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este ...

Страница 12: ...xii Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Preface Conventions ...

Страница 13: ...eclaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærksom på de involverede risici der er ved elektris...

Страница 14: ...xiv Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Preface Conventions ...

Страница 15: ...g additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The...

Страница 16: ...xvi Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Preface Obtaining Documentation and Submitting a Service Request ...

Страница 17: ...er Redundancy page 1 1 Catalyst 4503 E Switch Features page 1 2 Catalyst 4506 E Switch Features page 1 5 Supervisor Engine Redundancy page 1 8 Catalyst 4507R E Switch Features page 1 9 Catalyst 4510R E Switch Features page 1 13 Power Redundancy All Catalyst 4500 E switches offer 1 1 power redundancy so that in the event of a power interruption the switch can still operate using power from another ...

Страница 18: ...pervisor Engine V 10GE and Supervisor Engine 6 E The supervisor engine has a nonblocking full duplex switching fabric that provides connections between the supervisor engine and the switching modules Some supervisor engines use SFP modules for Gigabit Ethernet connections or X2 modules for 10 Gigabit Ethernet connections Refer to the installation note for your supervisor engine for more details on...

Страница 19: ...bays Power supplies Supports a 1000 W 1300 W 1400 W 2800 W or 4200W AC input power supply or a 1400 W DC input single input or triple input power supply1 Optional redundant power supply Supervisor engine support Supports the WS X4013 WS X4013 TS WS X4013 10GE WS X4515 WS X4516 WS X4516 10GE and WS X45 Sup6 E supervisor engines Holds the ASIC based forwarding engine data path and the management pro...

Страница 20: ... 6 port Gigabit Ethernet switching module WS X4506 GB T 18 port Gigabit Ethernet switching module WS X4418 GB 24 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4424 GB RJ45 48 port Gigabit Ethernet 1000 BASE LX SPF switching module WS X4448 GB LX 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4448 GB RJ45 24 port IEEE 802 3af compliant PoE 10 100 1000BA...

Страница 21: ...ng full duplex switching fabric that provides connections between the supervisor engine and the switching modules Some supervisor engines use SFP modules for Gigabit Ethernet connections or X2 modules for 10 Gigabit Ethernet connections Refer to the installation note for your supervisor engine for more details on these modules Slot 1 is reserved for the supervisor engine only which provides switch...

Страница 22: ...One hot swappable fan assembly Two power supply bays Power supplies Supports a 1000 W 1300 W 1400 W 2800 W or 4200 W AC input power supply or a 1400 W DC input single or triple input power supply1 Optional redundant power supply Supervisor engine support Supports the WS X4013 WS X4515 WS X4516 WS X4516 10GE and WS X45 Sup6 E Supervisor Engines Holds the ASIC based forwarding engine data path and t...

Страница 23: ...X4302 GB 6 port 1000BASE X Gigabit Ethernet switching module WS X4306 GB 6 port Gigabit Ethernet switching module WS X4506 GB T 18 port Gigabit Ethernet switching module WS X4418 GB 24 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4424 GB RJ45 48 port Gigabit Ethernet 1000 BASE LX SPF switching module WS X4448 GB LX 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m ...

Страница 24: ...OIR of the redundant supervisor engine Supervisor engine redundancy allows OIR of the redundant supervisor engine for maintenance When the redundant supervisor engine is inserted the active supervisor engine detects it The redundant supervisor engine boots into a partially initialized state in RPR mode and a fully initialized state in SSO mode Software upgrade Load the new image on the redundant s...

Страница 25: ...ching fabric that provides connections between the supervisor engine and the switching modules Some supervisor engines use SFP modules for Gigabit Ethernet connections or X2 modules for 10 Gigabit Ethernet connections Refer to the installation note for your supervisor engine for more details on these modules Slot 3 is reserved for the supervisor engine only which provides switching local and remot...

Страница 26: ...pment Seven slot modular chassis with one slot reserved for a supervisor engine one slot reserved for a redundant supervisor engine and five slots for switching modules Two power supply bays One hot swappable fan assembly Power supplies Can support a 1000 W 1300 W 1400 W 2800 W or 4200W AC input power supply or a 1400 W DC input single or triple input power supply1 Optional redundant power supply ...

Страница 27: ...T optional 2 port Gigabit Ethernet switching module WS X4302 GB 24 port 10 100BASE TX Fast Ethernet switching module WS X4124 RJ45 24 port 100BASE FX Fast Ethernet switching module WS X4124 FX MT 48 port 100BASE FX Fast Ethernet switching module WS X4148 FX MT 48 port 100BASE LX10 Fast Ethernet switching module WS X4148 FE LX MT 48 port 10 100 Mbps Fast Ethernet switching module WS X4148 RJ 48 por...

Страница 28: ...t 1000 BASE LX SPF switching module WS X4448 GB LX 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4448 GB RJ45 24 port IEEE 802 3af compliant PoE 10 100 1000BASE T RJ 45 switching module WS X4524 GB RJ45V 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4548 GB RJ45 48 port Gigabit Ethernet switching module WS X4448 GB SFP 48 port IEEE 802 3af complian...

Страница 29: ...ote for your supervisor engine for more details on these modules Slot 5 is reserved for the supervisor engine only which provides switching local and remote management and switch status monitoring Slot 6 is reserved for a redundant supervisor engine only Slots 1 2 3 4 7 8 9 and 10 are available for switching modules and provide up to 24 Gbps per slot 1 Fan Tray 3 Supervisor engines primary in slot...

Страница 30: ... high performance switches and routers 10 Gigabit Ethernet interfaces for backbone interconnection of high performance switches and routers Standard equipment Ten slot modular chassis with one slot reserved for a supervisor engine one slot reserved for a redundant supervisor engine and eight slots for switching modules Two power supply bays One hot swappable fan assembly Power supplies Can support...

Страница 31: ...odule WS X4148 RJ 48 port 100BASE BX10 D Fast Ethernet switching module WS X4148 FE BD LC 48 port 10 100 Mbps Fast Ethernet switching module WS X4148 RJ21 24 port IEEE 802 3af compliant PoE 10 100BASE TX switching module WS X4224 RJ45V 48 port IEEE 802 3af compliant PoE 10 100BASE TX RJ 45 switching module WS X4248 RJ45V 48 port 100BASE X Fast Ethernet switching module WS X4248 FE SFP 48 port IEEE...

Страница 32: ... X4424 GB RJ45 48 port Gigabit Ethernet 1000 BASE LX SPF switching module WS X4448 GB LX 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4448 GB RJ45 24 port IEEE 802 3af compliant PoE 10 100 1000BASE T RJ 45 switching module WS X4524 GB RJ45V 48 por t10 100 1000BASE T Gi gabi tEt her netswi t chi ng m odul e WS X4548 GB RJ45 48 port Gigabit Ethernet switching module WS X444...

Страница 33: ...sco IOS only VLANS Up to 4 096 VLANs with IEEE 802 1Q VLAN tagging on all ports and VLAN Trunking Protocol VTP Port aggregation PAgP1 for 100 Mbps and 1000 Mbps EtherChannel SNMP Full implementation including entity MIB all relevant standard MIBs and all relevant Cisco MIBs RMON The first four groups Ethernet statistics Alarms Events and History are on a per port basis without an optional RMON pro...

Страница 34: ...with Catalyst 4503 E full duplex Gigabit Ethernet switching engine Supervisor Engine V 96 Gbps 72 Mpps with Catalyst 4510R E 68 Gbps 51 Mpps with Catalyst 4507R E 64 Gbps 48 Mpps with Catalyst 4506 E 28 Gbps 21 Mpps with Catalyst 4503 E full duplex Gigabit Ethernet switching engine Supervisor Engine V 10GE 136 Gbps 101 Mpps with Catalyst 4510R E 68 Gbps 51 Mpps with Catalyst 4507R E 64 Gbps 48 Mpp...

Страница 35: ... WS X4013 10GE 2 GBIC uplink ports 6 Compact flash port 3 Switch load indicators 7 Reset button 4 Console port 1 Status LED 5 Management port 2 PoE status LED 6 Compact Flash port 3 Switch load indicators 7 Reset button 4 Console port 231961 1 2 3 4 5 6 7 1 Compact flash port 5 Gigabit SFP ports 2 Switch load indicator 6 Management port 3 RESET button 7 CONSOLE port 4 10GE uplink ports 8 STATUS LE...

Страница 36: ...ports 6 Compact flash port 3 switch load indicators 7 Reset button 4 Console port 231960 1 2 7 UPLINK UPLINK 2 UPLINKS ENABLED RESET 1 STATUS 1 100 4 3 5 UTILIZATION CONSOLE 10 100 MGT EJECT FLASH 6 1 Status LED 5 Management port 2 GBIC uplink ports 6 Compact Flash port 3 Switch load indicators 7 Reset button 4 Console port 231960 1 2 7 UPLINK UPLINK 2 UPLINKS ENABLED RESET 1 STATUS 1 100 4 3 5 UT...

Страница 37: ...these sections LEDs page 1 22 Gigabit Ethernet Uplink Ports page 1 22 10 Gigabit Ethernet Uplink Ports page 1 23 10 100BASE T Management Port page 1 23 CONSOLE Port page 1 23 1 Compact flash port 5 Gigabit SFP ports 2 Switch load indicator 6 Management port 3 RESET button 7 CONSOLE port 4 10GE uplink ports 8 STATUS LED 231961 EJECT 8 1 2 3 4 5 7 6 1 Status LED 6 Uplink ports 2 Reset button 7 USB p...

Страница 38: ...n the Catalyst 4510R to ports 3 and 4 only You can only use the 2 port Gigabit Ethernet switching module WS X4302 GB in slot 10 flex slot when a Supervisor Engine V is used Table 1 6 Supervisor Engine LEDs LED Color State Description STATUS Indicates the results of a series of self tests Green All diagnostic tests passed Red A test failed Orange System boot or diagnostic test is in progress or two...

Страница 39: ... available uplinks Slots 8 10 are intended for Catalyst 4500 classic switching modules only and all other slots may use classic or E series switching modules When two Supervisor Engine 6 Es are present in a Catalyst 4510R E or Catalyst 4507R E switch or two Supervisor Engine II Plus 10GEs are present in a Catalyst 4507R E one X2 uplink is active on both the primary active and secondary standby sup...

Страница 40: ...gines at the following URL http www cisco com en US docs switches lan catalyst4500 hardware configuration notes OL_2788 html Fan Assembly Note For complete environmental specifications including airflow requirements see Appendix A Specifications The system fan assembly provides cooling air for the internal chassis components The fan assembly is a tray of fans that you can insert and remove from th...

Страница 41: ...ltiple input power supply see Figure 1 16 The power supplies are hot swappable If you have power supplies of different types installed in the two bays only one will be active and some power features will not be available The power supply in the left bay is PS1 the one in the right bay is PS2 The AC input power supply has a power cord that connects each power supply to the site power source The DC ...

Страница 42: ... AC power supply should not be used in mixed voltage configurations All the inputs in a chassis must be the same voltage 110 or 220 V 1 AC receptacle 3 Captive screws 2 Power switch 231375 1 2 3 1 AC input 2 receptacle 4 AC input 1 receptacle 2 AC input 2 on switch 5 Captive screws 3 AC input 1 on switch 231376 100 120V 12A 50 60Hz 100 120V 12A 50 60Hz INPUT 1 OK INPUT 2 OK POE ENABLED 4600ACV OUT...

Страница 43: ...nal redundant power supply Each AC power supply has an individual power cord and status LEDs Systems with redundant power supplies will share the load with each unit providing approximately one half of the total load For information about configuring your switch for redundant and combined modes refer to the software configuration guide for your switch The Catalyst 4510R E requires at least 1400 W ...

Страница 44: ...en both power supplies in the chassis are the same type Table 1 7 Power Supply LEDs LED Color State Description INPUT OK Indicates whether the input voltage is within the required range Green Input voltage is within the required range Flashing Input voltage is present but is below required range Off Input voltage is below the required range or the power supply is off OUTPUT FAIL Red Output voltage...

Страница 45: ...d to greater than 56 V DC input PoE recovers after you recycle input power within the proper voltage range If the PoE shuts down due to input over voltage greater than 56 V DC the main converter section does not shut down The supervisor engine monitors the status of each power supply and provides a status report through the switch software For more details on how the supervisor engine monitors the...

Страница 46: ... a minimum draw from the system that it is installed in Table 1 11 shows the minimum draw for the possible modes Table 1 9 Combined Mode Power Supply Configuration 2450 W Max Output Power Input Number Maximum Input Current Maximum Input Power 44 V DC 1 12 5 A 44 V DC 550 W 2 15 A 44 V DC 660 W 3 15 A 44 V DC 660 W Table 1 10 Dual Redundant Mode Power Supply Configuration 1400 W Max Output Power In...

Страница 47: ...3 E switch is shown in the examples Mode 5 ON ON ON 4A 0 6A Dual Redundant Operation Mode 1 ON OFF OFF ON OFF OFF 2 66A 1 2A Mode 2 OFF ON OFF OFF ON OFF 2 66A 1 2A OFF OFF ON OFF OFF ON 2 66A 1 2A Mode 3 ON ON OFF ON ON OFF 5 32A 1 2A ON OFF ON ON OFF ON 5 32A 1 2A Mode 4 OFF ON ON OFF ON ON 5 32A 1 2A Mode 5 ON ON ON ON ON ON 8A 1 2A Table 1 11 Minimum Load Table continued PSU1 PSU2 Input 1 Inpu...

Страница 48: ...erters that use the 12 V circuit to provide PoE to powered devices connected to the Supervisor engine only If your system has a Supervisor Engine II Plus TS in slot 1 you still need a PoE enabled power supply to provide PoE to the other slots All Catalyst 4500 E series switches support dual power supplies configurable for combined mode or redundant mode In combined mode the switch has available th...

Страница 49: ...ered devices 2 Configure ports to be in static mode This is for ports that have highest priority such as phones for executives or wireless access points If ports need to be disabled because of a power shortage auto ports are disabled before static ports 3 Configure the maximum wattage on ports to be less than the default based on the maximum power consumption of the powered device This disallows d...

Страница 50: ...ly deployments which typically require just a few hundred watts For deployments that dictate support for PoE power Cisco offers several options The Cisco Catalyst 4500 E series offers several internal supplies 1000 W AC data only 1400 W AC data only 1300 W data and PoE 1400 W DC data and PoE 2800 W data and PoE and 4200 W AC data and PoE When more than 4200 W of redundant data and PoE are required...

Страница 51: ...Flow Each system component has an EEPROM that identifies it to the supervisor engine over a serial connection on the backplane which also passes along information like temperature fan speed power draw per slot and port and port activity LED status information is also sent to the supervisor engine which makes it available to an administrator through a terminal connection or management software All ...

Страница 52: ...d and Catalyst 4500 E Series 48 port 10 100 1000 Switching modules are 2 1 oversubscribed On both types of switching modules there are multiplexing ASIC s which group the front panel ports and multiplex them to the internal switch fabric On a 48 port 10 100 1000 Classic Catalyst 4500 Series switching module eight front panel ports are multiplexed into a a single nonblocking full duplex Gigabit Eth...

Страница 53: ...t 1 1 supervisor engine redundancy for integrated resiliency Redundant supervisor engines help minimize network downtime With the support of stateful switchover SSO the secondary supervisor engine serves as a backup to immediately take over after a primary supervisor failure During the switchover Layer 2 links are maintained transparently without the need to renegotiate sessions As a result busine...

Страница 54: ...1 38 Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Chapter 1 Product Overview System Architecture ...

Страница 55: ...ing Class 1 laser product Statement 1008 If you will be using your switch as a PoE source the following warning applies Warning Voltages that present a shock hazard can exist on inline power circuits if interconnections are made by using uninsulated exposed metal contacts conductors or terminals Avoid using such interconnection methods unless the exposed metal parts are in a restricted access loca...

Страница 56: ...mage Ground the cable before connecting the networking equipment You can create a grounding cable using an RJ 45 patch cable by doing the following Bare the wires on one end Connect the wires to a suitable and safe earth ground Connect the RJ 45 cable to a female RJ 45 connector Briefly connect all cables to the grounded cable before connecting to networking equipment Leave cables from the network...

Страница 57: ...all the switch For more information about power management and planning refer to the Environmental Monitoring and Power Management chapter in the Catalyst 4500 Series Switch Cisco IOS Software Configuration Guide version appropriate for your software Knowing the power requirements is useful for planning the power distribution system needed to support the switches You should consider the heat dissi...

Страница 58: ...upplies for other countries the plugs shown are the same for the 1000 W and 1300 W power supplies 1400 W Table 2 1 lists the AC input power cord options specifications and Cisco product numbers and shows the different styles of 1400 W AC input power cord wall plugs that are available for North America or various international locations as well as the appliance coupler that is attached to the power...

Страница 59: ...NEMA 5 15P Australia New Zealand CAB 7KACA 8 2 ft 2 5 m 250 VAC 15 A SAA 3 AS NZS 3112 1993 Europe except Italy CAB 7KACE 8 2 ft 2 5 m 250 VAC 16 A CEE 7 7 Italy CAB 7KACI 8 2 ft 2 5 m 250 VAC 16 A 1 3 16 CEI 23 16 United Kingdom CAB 7KACU 8 2 ft 2 5 m 250 VAC 13 A BS 89 13 BS 1363 A Argentina CAB 7KACR 8 2 ft 2 5 m 250 VAC 10 A IRAM 2073 1300 W PWR C45 1300ACV and 1400 W PWR C45 1400AC Power Supp...

Страница 60: ...23 16 United Kingdom CAB 7513ACU 14 ft 4 3 m 250 VAC 13 A BS 89 13 BS 1363 A Argentina CAB 7513ACR 14 ft 4 3 m 250 VAC 10 A IRAM 2073 North America locking 200 240 VAC operation CAB AC 2800W TWLK 13 6 ft 4 1 m 250 VAC 16 A NEMA L6 20 North America non locking 200 240 VAC operation CAB AC 2800W 6 20 13 2 ft 4 0 m 250 VAC 16 A NEMA 6 20 non locking Europe CAB AC 2800W EU 13 2 ft 4 0 m 250 VAC 16 A C...

Страница 61: ... 240 VAC operation CAB AC 2800W 6 20 13 2 ft 4 0 m 250 VAC 16 A NEMA 6 20 non locking Europe CAB AC 2800W EU 13 2 ft 4 0 m 250 VAC 16 A CEE 7 7 International CAB AC 2800W INT 13 6 ft 4 1 m 250 VAC 16 A IEC 309 4200 W Power Supply PWR C45 4200ACV Appliance Coupler North America 120 VAC operation CAB US515P C19 US 9 8 ft 2 98 m 125VAC 15A NEMA 5 15P North America locking 200 240 VAC operation CAB L6...

Страница 62: ...ca CAB I309 C19 INT 13 6 ft 4 1 m 250 VAC 16 A IEC 309 Australia CAB A3112 C19 AUS 14 ft 4 3 m 250 VAC 15 A AS NZZS 3112 Italy CAB C2316 C19 IT 14 ft 4 3 m 250 VAC 16 A CEI 23 16 United Kingdom CAB BS1363 C19 UK 14 ft 4 3 m 250 VAC 15 A BS 1363 Israeli CAB S132 C19 ISRL 14 ft 4 3 m 250 VAC 16 A SI32 UPS 220V CAB C19 CBN 9 ft 2 74 m 250 VAC 20 A IEC 60320 C20 UPS 110V CAB C19 C14 14 ft 4 3 m 125 VA...

Страница 63: ...that the power cables are connected to the DC input power supply terminal block in the proper and polarity In some cases the source DC cable leads might have a positive or a negative label This label is a relatively safe indication of the polarity but you must verify the polarity by measuring the voltage between the DC cable leads When making the measurement the positive lead and the negative lead...

Страница 64: ...ir is too warm an overtemperature condition can occur The switch environmental monitor can then shut down the system to protect the system components To ensure normal operation and avoid unnecessary maintenance plan your site configuration and prepare your site before installation After installation make sure the site maintains an ambient temperature of 0 to 40ºC 32 to 104ºF It is essential to kee...

Страница 65: ... Note Although a class 3 device needs 15 4 W to power up 17 3 W need to be generated from the backplane in order to have 15 4 W at the switch port 17 3 W comes from the WS X4248 RJ45V DC DC converter s efficiency 89 Site Planning Checklist Table 2 2 lists the site planning activities that you should complete before you install a Catalyst 4500 E series switch Completing each activity helps to ensur...

Страница 66: ...ccess 2 Environmental evaluation Ambient temperature Humidity Altitude Atmospheric contamination Airflow 3 Power evaluation Input power type Receptacle proximity to the equipment Dedicated separate circuits for redundant power supplies UPS for power failures 4 Grounding evaluation Circuit breaker size 5 Cable and interface equipment evaluation Cable type Connector type Cable distance limitations I...

Страница 67: ...series switches in a rack For first time installations perform the procedures in the following sections in the order listed Checking the Shipping Container Contents page 3 1 Rack Mounting the Switch page 3 2 Note Before starting the installation procedures in this chapter complete the site planning checklist in Table 2 2 of Chapter 2 Preparing for Installation Note For information on installing th...

Страница 68: ...ting the switch in a standard 19 inch 48 3 cm equipment rack with two unobstructed outer posts with a nominal depth between the front and rear mounting posts of 19 25 inches 48 9 cm and a maximum depth of 32 inches 81 3 cm This kit is not suitable for racks with obstructions such as a power strip that could impair access to the field replaceable units FRUs of the switch Alternatively you can obtai...

Страница 69: ...t front mounting posts to ensure that it is 17 75 inches 45 09 cm wide The chassis is 17 25 inches 43 8 cm wide and must fit between the mounting posts Note Some equipment racks provide a power strip along the length of one of the rear posts If your rack has this feature consider the position of the strip when planning fastener points Before installing the L brackets on the chassis determine wheth...

Страница 70: ...rt the rear of the chassis between the mounting posts See Figure 3 2 to see how to install a Catalyst 4506 E switch in a rack Other switches in the series mount in the same manner b Align the mounting holes in the L bracket with the mounting holes in the equipment rack c Secure the chassis using at least six three per side 12 24 x 3 4 inch screws through the elongated holes in the L bracket and in...

Страница 71: ...ive installation screws on the supervisor engine and the switching module Step 5 Connect fiber and copper cables for switching traffic and uplinks or PoE as appropriate Step 6 Connect the switch to an appropriate ground Refer to System Ground Connection Guidelines page 3 5 The system must have a ground connection before power is supplied to the switch System Ground Connection Guidelines A groundin...

Страница 72: ... 2 Phillips screwdriver Crimping tool This tool must be large enough to accommodate the girth of the grounding lug when you crimp the grounding cable into the lug Wire stripping tool Connecting System Ground and Power This section describes how to connect the Catalyst 4500 E series switches to earth ground The system ground connection is required if FXS modules are installed or if this equipment i...

Страница 73: ... Repeat steps 1 through 3 to prepare the other end of the grounding wire and connect it to an appropriate grounding point at your site to ensure adequate earth ground for the switch Step 9 Connect the power supply cords DC power supplies will have a separate ground connection both chassis and power supply grounds are needed for the system The switch comes on when the cords are connected and the po...

Страница 74: ...uld use the RJ 45 to RJ 45 rollover cable to connect the console port to a PC that runs terminal emulation software Configure your terminal emulation program for 9600 baud 8 data bits no parity no flow control and 1 stop bit With this console connection you can configure the switch as described in Appendix C Initial Configuration for the Switch and then as discussed in the software configuration g...

Страница 75: ...ent 1024 Warning Before working on equipment that is connected to power lines remove jewelry including rings necklaces and watches Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals Statement 43 Warning Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 Th...

Страница 76: ...ly page 4 8 Installing a DC Input Power Supply page 4 11 Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Statement 1034 Figure 4 1 and Figure 4 2 show the AC input power supplies Figure 4 3 and Figure 4 4 show a the DC input power supplies Locate your power supply and notice the location of the captive installation screws Note...

Страница 77: ...pply Figure 4 3 DC Input Power Supply 1 AC input 2 receptacle 4 AC input 1 receptacle 2 AC input 2 on switch 5 Captive screws 3 AC input 1 on switch 231376 100 120V 12A 50 60Hz 100 120V 12A 50 60Hz INPUT 1 OK INPUT 2 OK POE ENABLED 4600ACV OUTP UT FAI FAN OK 4 5 3 2 1 Captive screw Captive screw In line power switch Serial communication connector Main power switch Terminal block 79160 ...

Страница 78: ...orm these procedures Removing an AC Input Power Supply Follow these steps to remove the AC input power supply Step 1 Press the power switch on the AC input power supply down to the off O position see Figure 4 5 Figure 4 5 Powering Off the Power Switch Note There are two on off switches on a 4200 W AC power supply one for each input Step 2 Loosen the side clamp screw on the right side of the power ...

Страница 79: ...ew Step 3 Disconnect the power cord from the power supply being removed Step 4 Loosen the two captive screws see Figure 4 7 Figure 4 7 Loosening the Captive Screws Caution Use both hands to grasp a power supply Step 5 Grasp the power supply handle with one hand Place your other hand underneath to support the bottom of the power supply as shown in Figure 4 8 79139 Captive screws 79140 ...

Страница 80: ...ver the opening Secure the filler plate with the two mounting screws and tighten them with a screwdriver Installing an AC Input Power Supply Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Follow these steps to install an AC input power supply Step 1 Make sure that the power supply you are installing is not plugg...

Страница 81: ... 4 9 Figure 4 9 Plugging the Power Cord into the Power Supply Step 10 Connect the other end of the power cord to an AC power input source Caution In a system with multiple power supplies connect each power supply to a separate AC power source In the event of a power source failure if the second source is still available it can maintain maximum overcurrent protection for each power connection Step ...

Страница 82: ...move a DC input power supply Required Tools You will need the following tools to perform this procedure A Phillips screwdriver A 10 mm wrench socket Removal Procedure Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Follow these steps to remove a DC input power supply Step 1 Turn off the in line power switch Single input only...

Страница 83: ...rminal block Disconnect the ground wire last see Figure 4 13 or Figure 4 14 Warning When installing or replacing the unit the ground connection must always be made first and disconnected last Statement 1046 Captive screw Captive screw In line power switch Serial communication connector Main power switch Terminal block 79160 231891 Power switch 1 2 3 Terminal block Ground lugs Input OK 1 2 3 LEDs F...

Страница 84: ...g a screwdriver loosen and remove the captive screws on the power supply See Figure 4 15 which shows the single input power supply The triple input power supply has captive screws in the same location Figure 4 15 Loosening the Captive Screws RS 485 serial communnication connector 79161 Grounding lug Grounding lug nuts DC input wires Negative Positive Ground 231892 1 2 3 Grounding lugs 2 Grounding ...

Страница 85: ...ccidental contact with live voltage at the rear of the bay Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do not operate the system unless all cards facepla...

Страница 86: ... DC input power supply connect it to a power source and verify its operation Step 1 Verify that power is off to the DC circuit or circuits on the power supply you are installing Step 2 Grasp the power supply handle with one hand Place your other hand underneath it as you slowly insert the power supply into the bay as shown earlier in Figure 4 16 Step 3 Using a screwdriver tighten the captive screw...

Страница 87: ...the LEDs or the show power command Cisco IOS output indicate a power problem or other system problem see Chapter 5 Troubleshooting for more information Removing and Replacing the Chassis Fan Assembly This section describes how to remove and install the chassis fan assembly for the Catalyst 4500 E series switches See Figure 4 17 for the Catalyst 4506 E system fan assembly other fan assemblies attac...

Страница 88: ...afe place Installing the Fan Assembly Follow these steps to install the new fan assembly Step 1 Hold the fan assembly with the fans facing to the right Step 2 Place the fan assembly into the fan assembly bay so it rests on the chassis and then lift the fan assembly up slightly aligning the top and bottom guides Step 3 Slide the fan assembly into the chassis until the two captive installation screw...

Страница 89: ...module on a Catalyst 4507R E chassis backplane A Catalyst 4510R E has 8 redundancy modules on its backplane They are accessible from the front if the switching modules and supervisor engines are removed There are two types of redundancy modules and they are interchangeable The clock module replacement procedure is identical to the redundancy module replacement procedure the connectors are the same...

Страница 90: ...ock module remove the two screws that attach the module to the backplane Step 5 Find the seating levers on both sides of the connector for the module you wish to replace See Figure 4 19 Figure 4 19 Finding the Seating Levers Step 6 To release the module from its connector pull the levers outward with your fingernails The module will pop out slightly See Figure 4 20 Mux buffers Clock module 130657 ...

Страница 91: ...ners See Figure 4 21 Note When handling the modules do not touch the chips or the gold edge contacts on the module Figure 4 21 Removing the Module Step 8 Put the replacement module in at roughly a 30 degree angle and gently push the module down Make sure you apply force evenly on the left and right See Figure 4 22 Figure 4 22 Seating the Replacement Module Step 9 Make sure the module is fully seat...

Страница 92: ...erify the New Modules After the switch is reassembled and power is restored connect a terminal to the supervisor engine and monitor the boot process Look for the following messages or any others which may indicate a problem with the replaced modules 00 00 20 C4K_SUPERVISOR 2 MUXBUFFERNOTPRESENT Mux buffer WS X4K MUX 3 is not present 00 00 20 C4K_SUPERVISOR 2 MUXBUFFERNOTPRESENT Mux buffer WS X4K M...

Страница 93: ... can be upgraded to 1 GB in the form of an SDRAM miniDIMM Tools and Equipment Needed You need the following tools and equipment to remove and install miniDIMMs in a Supervisor Engine 6 E Number 2 Phillips screwdriver Small flat blade screwdriver ESD preventive wrist strap Antistatic mat Removing Memory You will not need to remove the base memory to perform a memory upgrade but it may make installi...

Страница 94: ...MM by the edges only do not touch the memory modules pins or traces metal fingers along the connector edge Handle carefully MiniDIMMs are ESD sensitive components and can be damaged by mishandling Step 3 Release the metal clips from the miniDIMM which releases the miniDIMM from its socket See Figure 4 26 1 Lower slot u50 Additional memory to be installed in this slot 2 Upper slot u39 base memory i...

Страница 95: ...M MiniDIMMs follow these steps Step 1 Attach an ESD preventive wrist strap and ensure that it makes good contact with your skin Connect the equipment end of the wrist strap to the metal back plate of the chassis avoiding contact with the connectors Step 2 On the mainboard locate the SDRAM miniDIMM sockets See Figure 4 25 Caution Handle the miniDIMM by the edges only do not touch the memory modules...

Страница 96: ...ep 4 Tilt the miniDIMM to the same angle as the socket then insert the connector edge into the socket Gently push into place until the metal clips snap into place Caution It is normal to feel some resistance when installing a miniDIMM but do not use excessive force and do not touch the surface components Step 5 Check the two alignment holds and ensure that the metal clips are visible If necessary ...

Страница 97: ...elease notes or Error Message Decoder tool Information specific to your software release can be found in the software configuration guide for that release or in the system message guide for your release The following links may be useful in combination with this chapter Release notes http www cisco com en US products hw switches ps4324 prod_release_notes_list html Error Message Decoder http www cis...

Страница 98: ... and 1 stop bit Watch for any system messages after startup That the power supplies are supplying power to the system The power supply s LEDs should be green Use the show environment Cisco IOS command to view power supply activity That the system fan assembly is operating Listen for fan activity The Fan tray LED should be green during operation Use the show environment Cisco IOS command to view fa...

Страница 99: ...e LED labeled STATUS on the supervisor engine front panel is red or orange connect a console to the management port and use the show environment command to check for possible problems The Ethernet management port LED turns green when the module is operational online and a link is established with another network device If no signal is detected the LED labeled LINK turns off If there is a problem w...

Страница 100: ... http www cisco com en US products hw switches ps4324 prod_release_notes_list html Troubleshooting the Power Supply To help isolate a power subsystem problem follow these steps Step 1 Check whether the power supply LED labeled GOOD is on or the LED labeled FAIL is on on the DC multi input power supply the LEDs are labeled INPUT 1 2 or 3 or OUTPUT FAIL Step 2 If the LED labeled GOOD is off or if th...

Страница 101: ... power supply or upgrade to a larger one for your current configuration or verify that the switches are set properly on the power supply Connect a terminal to the console port and look for any of the following system messages there may be others depending on the software release C4K_CHASSIS 2 INLINEPOWEROFF C4K_IOSMODPORTMAN 4 INLINEPOWERSUPPLYBAD C4K_IOSMODPORTMAN 4 INLINEPOWEROVERMAX C4K_CHASSIS...

Страница 102: ...must be operating or a failure will occur Environmental problems may initially appear to be problems with the fan tray To help isolate a fan assembly problem follow these steps Step 1 Check the status LED on the fan tray If the LED is off and the rest of the system is functioning the fan tray is not getting power or is not seated correctly on the backplane If the LED is green the fans are operatin...

Страница 103: ...tions for your situation http www cisco com cgi bin Support Errordecoder index cgi Useful CLI Commands The show environment status fantray command can give additional information useful in diagnosing fan tray problems Troubleshooting Backplane Modules The Cisco Catalyst 4500 E series redundancy scheme uses removable redundancy modules also called mux buffers on the passive backplane to switch traf...

Страница 104: ...d behavior Figure 5 1 Gigabit Ethernet Port and Status LEDs Figure 5 2 10 100BASE T Port LEDs 1 26854 1000BASE X SWITCHING MODULE STATUS 2 3 WS X4306 GB GIGABIT ETHERNET Table 5 1 Switching Module LEDs LED Color State Description STATUS Indicates the results of a series of self tests and diagnostic tests performed by the switch Green All the tests pass Red A test other than an individual port test...

Страница 105: ...ng module Use the hw module module n reset command to reset a switching module or remove and re insert the switching module which resets restarts and power cycles the switching module The show module and show diagnostics online module commands can also provide information useful in solving problems with ports on individual modules Not all software versions support all switching modules If you are ...

Страница 106: ...3 TEMPERATURESENSORREADFAILED C4K_HW 3 X2IDENTIFICATIONFAILURE Table 5 2 Supervisor Engine LEDs LED Color State Description STATUS Indicates the results of a series of self tests Green All diagnostic tests passed Red A test failed Orange System boot or diagnostic test is in progress Off Module is disabled UTILIZATION Green 1 100 If the switch is operational this display indicates the current traff...

Страница 107: ..._SUPERVISOR 3 RETIMERINITFAILED C4K_SUPERVISOR 3 SEEPROMREADFAILED C4K_SUPERVISOR 4 INLINEVOLTAGEOUTOFRANGE C4K_SUPERVISOR 7 SEEPROMWRITEFAILED C4K_SWITCHMANAGER 3 SSOACTIVEPORTACKTIMEOUT C4K_SYSMAN 2 POWERONSELFTESTFAIL These system messages indicate a problem with the supervisor engine Some problems will prevent a console connection and will not allow you to use messages in diagnosing a problem ...

Страница 108: ...mand or an amber status LED create a console connection to the standby supervisor engine and verify that it is in ROMmon mode or in continuous reboot If the standby supervisor engine is in either of these two states refer to http www cisco com en US products hw switches ps663 products_configuration_example09186a008 0094ecf shtml switch show module Mod Ports Card Type Model Serial No 1 2 1000BaseX ...

Страница 109: ...as never crashed Switch more crashinfo data Current time 04 21 2000 19 58 10 Last crash 04 21 2000 03 58 56 Output suppressed If the output indicates a software crash at the time that you suspect that the switch rebooted the problem can be something other than a hardware failure Contact Cisco Technical Support with the output of these commands show tech support show logging more crashinfo data If ...

Страница 110: ...umber and manufacturer of the power supplies c Contact Cisco Technical Support with the information that you collected Note If Cisco Technical Support did not assist with the troubleshoot procedure you must provide the information in the order of these steps Some Problems and Solutions Module Not Online Part or all of the module can fail to come online You may have a module failure if you see an a...

Страница 111: ... products hw switches ps700 products_tech_note09186a008015bfd6 shtm l Workstation Is Unable to Log In to the Network If you observe that a workstation is unable to log into the network during startup or unable to obtain the DHCP address when you have powered up a client machine or rebooted an initial connectivity delay that the switch introduced could be the problem To verify this check the follow...

Страница 112: ...atus command some possible reasons include Duplex mismatch Port channel misconfiguration Bridge protocol data unit BPDU guard violation UniDirectional Link Detection UDLD condition Late collision detection Link flap detection Security violation Port Aggregation Protocol PAgP flap Layer Two Tunneling Protocol L2TP guard DHCP snooping rate limit In order to troubleshoot these scenarios refer to the ...

Страница 113: ...ster recovery of absent or corrupt images Cannot Connect to a Switch Through the Console Port Make sure you are using the correct type of cable Make sure the terminal configuration matches the switch console port configuration default console port settings are 9600 baud 8 data bits no parity 1 stop bit Make sure the cable pinouts are correct for your supervisor engine refer to the hardware documen...

Страница 114: ...tely bypassing listening and learning modes do not use this feature for connections to non end station devices b Disable trunking on the port use the set trunk mod_num port_num off command c Disable channeling on the port use the set port channel port_list off command you must specify a valid port range with this command you cannot specify a single port Step 14 Make sure the switch is learning the...

Страница 115: ...eady taken to isolate and resolve the problem See the Obtaining Documentation and Submitting a Service Request section on page xv for more information about contacting the TAC Serial Numbers When you contact TAC have the serial number of your switch available Refer to Figure 5 3 to locate the serial number on your switch You may also get the serial number from the output of a show version or show ...

Страница 116: ...5 20 Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Chapter 5 Troubleshooting Contacting the Cisco Technical Assistance Center ...

Страница 117: ...es including power consumption and thermal output information are in the Catalyst 4500 Series Module Installation Guide available online at http www cisco com en US docs switches lan catalyst4500 hardware module guide mod_inst html Catalyst 4503 E Switch Specifications Table A 1 lists the Catalyst 4503 E switch specifications Table A 1 Catalyst 4503 E Switch Specifications Item Specification Envir...

Страница 118: ... Physical Characteristics Dimensions H x W x D 12 25 x 17 31 x 12 50 in 311 15 mm x 439 7 mm x 317 5 mm Weight Minimum weight 32 25 lbs 14 65 kg Maximum weight 75 lbs 34 kg Chassis and backplane 32 25 lbs 14 65 kg Fan tray 2 75 lbs 1 24 kg Airflow Switch Right to left Power supply Front to back Power PoE supplied 48 VDC Power to Modules and fans 12 VDC Power to backplane components 3 3 VDC Redunda...

Страница 119: ...H x W x D 17 38 x 17 31 x 12 5 in 441 3 x 439 7 x 317 5 mm Weight Minimum weight 34 5 lbs 15 6 kg Maximum weight 100 lbs 45 4 kg Chassis and backplane 39 5 lbs 17 95 kg Fan tray 5 0 lbs 2 2 kg Airflow Switch Right to left Power supply Front to back Power PoE supplied 48 VDC Power to Modules and fans 12 VDC Power to backplane components 3 3 VDC Redundancy Supervisor engine no Power supply 1 1 Table...

Страница 120: ...40 max 10 100 1000 ports Two 10 Gbps Uplinks and up to 30 10 Gbps ports on switching module slots Inline power integrated support 820 W per line card Physical Characteristics Dimensions H x W x D 19 15 x 17 22 x 12 5 in 49 x 44 x 32 cm Weight Minimum weight 45 5 lbs 20 68 kg Maximum weight 100 lbs 45 4 kg Chassis and backplane 45 5 lbs 20 68 kg Fan tray 6 lbs 2 7 kg Airflow Switch Right to left Po...

Страница 121: ... Engine V 96 Gbps with Supervisor Engine V 10GE 386 Gbps with Supervisor Engine 6 E 4 Gbps Uplinks with Sup II Sup IV and Sup 6 E with TwinGig converters 8 Gbps Uplinks with Supervisor Engine V 20 Gbps Uplinks with Supervisor Engine V 10GE two 10 Gbps Uplinks with Sup V 10GE and Sup 6 E Port density 386 maximum 10 100 1000 ports Two 10 Gbps Uplinks and up to 30 10 Gbps ports on switching module sl...

Страница 122: ...supplies or multiple AC power plugs on the same power supply because all AC power supply inputs are isolated Each chassis power supply should have its own dedicated branch circuit 15 A or 20 A for North America and circuits sized to local and national codes for International locations For more information about power management and planning refer to the Environmental Monitoring and Power Managemen...

Страница 123: ...minal 3 Hz for full range Power supply output capacity 1050 W plus 40 W fan Power supply output 12 V 83 4 A 3 3V 12 2 A 1667 W maximum Output holdup time 20 ms minimum Max heat dissipation 943 BTUs hr Table A 6 1300 W AC Input Power Supply Specifications Item Specification Minimum software requirement Cisco IOS Release 12 1 12c EW Power over Ethernet Supported up to 800 W 211 Cisco phones in combi...

Страница 124: ...bl et o pr ovi dePoE AC input type Autoranging input with power factor corrector AC input voltage 100 to 240 VAC 10 for full range AC input current 16 A 100 VAC 7 A 240 VAC AC input frequency 50 60 Hz nominal 3 Hz for full range Maximum KVA rating 1 76 KVA Power supply output 2473 W maximum 1360 W 40 W redundant mode Data Power supply output AC supply 12 V 113 4 A 3 3 V 12 2 A Data Max heat dissip...

Страница 125: ...el type lug terminals with 90 degree angle two hole tongue which accommodates 1 0 AWG size copper wire The connector tongue width is 0 82 in the stud hole spacing is 5 8 in and the hole size is 1 4 in Output holdup time 4 ms Max heat dissipation 1591 BTUs hr data 2905 BTUs hr data and voice Catalyst 4503 Specific Power Usage data only Maximum draw 475 W Maximum input 633 W Current draw at 40 5 V m...

Страница 126: ...to 60 VDC Input 3 15 A at 48 to 60 VDC Input power Current draw At 40 5 V min voltage Current draw at 72 V max voltage Max heat dissipation at 1400 W 1772 W 1400 W output power 42 5 A 25 A 1269 BTUs Maximum KVA rating 1 77 at 1400 W load Power supply output DC supply 12 V 8 A minimum 115 3 A maximum 3 3 V 1 2 A minimum 12 5 A maximum 1360 W 40 W redundant mode 2450 W maximum in combined mode DC in...

Страница 127: ...n voltage Current draw at 72 V max voltage 26 6 A total of modules A per module 15 A total of modules A per module Max heat dissipation at 1076 W 3671 BTUs Catalyst 4507R Specific Power Usage data only Three modules minimum required Maximum draw data only 1080 W Max input is 1080 W 1367 W total of modules W per module Current draw at 40 5 V min voltage Current draw at 72 V max voltage 33 75 A tota...

Страница 128: ...t type Autoranging input with power factor corrector AC input voltage 200 to 240 VAC 10 for full range AC input current 16 A maximum at 200 VAC AC input frequency 50 60 Hz nominal 3 for full range Maximum KVA rating 3 52 KVA Power supply output 2800 W maximum 12 V 113 3 A 3 3 V 12 1 A Data 50 V 28 A PoE 1360 W 40 W redundant mode Data 2473 W maximum in combined mode Data 1400 W maximum each in red...

Страница 129: ...ed mode Maximum KVA rating 5 25 KVA Power supply output 4200 W maximum 230 VAC 12 V 115 3 A 3 3 V 12 5 A Data 50 V 77 1 A PoE with two inputs 2100 W maximum 230 VAC 12 V 115 3 A 3 3 V 12 5 A Data 50 V 38 5 A PoE with one input 2100 W maximum 120 VAC 12 V 115 3 A 3 3 V 12 5 A Data 50 V 38 0 A PoE with two inputs 1050 W maximum 120 VAC 12 V 55 9 A 3 3 V 12 5 A Data 50 V 14 6 A PoE with one input Max...

Страница 130: ...E 347 200 200 1182 3 85 2 89 1 93 1 44 WS X4606 X2 E 173 130 80 227 0 74 0 56 0 37 0 28 WS X4648 RJ45V E 123 92 10 418 1 36 1 02 0 68 0 51 WS X4648 RJ45V E 123 92 10 418 1 36 1 02 0 68 0 51 Table A 17 DC Power Requirements and Heat Dissipation Specifications Model Number Module Type DC Input Power W DC Output Power W Heat Dissipation BTU Hr Input Current at 42 VDC A Input Current at 48 VDC A Input...

Страница 131: ... the original packaging material follow these steps Step 1 Slide the pieces of the packing foam over the Catalyst 4500 E series switch See Figure B 1 Step 2 Place the documentation and accessory kit in the box or poly bag provided Step 3 Place the box or poly bag containing the documentation and accessory kit on top of the packing material Step 4 Place the switch with packing foam pieces into the ...

Страница 132: ...eries Switches Installation Guide OL 13972 01 Appendix B Repacking a Switch Figure B 1 Catalyst 4500 E series Switch Packing Material Packing carton Packing foam Packing foam Packing foam Documentation and accessories 68117 ...

Страница 133: ...te If you are using a DC power supply see the Power Connection Guidelines for DC Powered Systems section on page 2 9 for more information about setting up your switch with a DC power supply Note You need to provide the Category 5 straight through cables to connect the switch ports to other Ethernet devices Note If you move a supervisor engine from a Catalyst 4500 series chassis to a Catalyst 4503 ...

Страница 134: ...n so that you can see the output display from the power on self test POST The terminal emulation software frequently a PC application such as Hyperterminal or ProcommPlus makes communication between the switch and your PC or terminal possible Step 1 Start the terminal emulation program if you are using a PC or terminal Step 2 Start a terminal emulation session Step 3 Configure the baud rate and ch...

Страница 135: ...formation necessary for the switch to communicate with the local routers and the Internet The minimal configuration provided here does not cover most of the features it simply allows you to preform other configuration tasks using a telnet connection from your management network To configure other features and interfaces please refer to the Catalyst 4500 Series Switch Software Configuration Guide I...

Страница 136: ...an start with a number is case sensitive allows spaces but ignores leading spaces The secret password is encrypted and the enable password is in plain text Switch1 config enable secret SecretPassword Step 8 Configure an enable password and press Return Switch1 config enable password EnablePassword Step 9 Configure a virtual terminal Telnet password and press Return The password can be from 1 to 25...

Страница 137: ...rnal type 2 E EGP i IS IS L1 ISIS level 1 L2 ISIS level 2 ia ISIS inter area candidate default U per user static route o ODR P periodic downloaded static route Gateway of last resort is 172 16 1 1 to network 0 0 0 0 172 16 0 0 24 is subnetted 1 subnets C 172 16 1 0 is directly connected Vlan1 S 0 0 0 0 0 1 0 via 172 16 1 1 Switch1 Step 15 Save the running configuration Switch1 copy system running ...

Страница 138: ...C 6 Catalyst 4500 E Series Switches Installation Guide OL 13972 01 Appendix C Initial Configuration for the Switch Entering the Initial Configuration Information ...

Страница 139: ...e designed for high performance high density wiring closet applications A detailed overview of these switches is in the Catalyst 4500 Series Installation Guide Catalyst 4500 E Series Switches The Catalyst 4500E series switches consist of the Catalyst 4503 E switch the Catalyst 4506 E switch the Catalyst 4507R E switch and the Catalyst 4510R E switch The switches are designed for high performance h...

Страница 140: ...e supervisor engines have the following features Data path and control for all network interfaces Management functions Interface monitoring Environmental status SNMP and console Telnet interface Hot swapping Note Packets are not forwarded while the module is removed A system reboot occurs when a supervisor engine is reinserted To install a supervisor engine follow the procedure in its installation...

Страница 141: ...act Flash on the Catalyst 4500 Supervisor Engines The Twin Gig ports are the modules described in http www cisco com en US products ps7077 prod_module_installation_guide09186a00807e0ca4 html Table D 1 describes the supervisor engine LEDs Table D 1 Supervisor Engine LEDs LED Color State Description STATUS Indicates the results of a series of self tests Green All diagnostic tests passed Red A test f...

Страница 142: ...le The console port allows you to perform the following functions Configure the switch from the CLI Monitor network statistics and errors Configure SNMP agent parameters Download software updates to the switch or distribute software images residing in Flash memory to attached devices Note EIA TIA 232 was known as recommended standard RS 232 before its acceptance as a standard by the Electronic Ind...

Страница 143: ... following specifications Specification Description Module type 10Gig X2 or TwinGig fiber Ethernet switching module Port duplex mode Full duplex mode Port speed 10 Gbps or 2 Gbps when using a Cisco TwinGig converter and 2 SFPs Number of ports 6 Connector type SC type Cable type MMF or SMF 211397 Specification Description Module type 10 100 1000BASE T Fast Ethernet switching module with IEEE802 3af...

Страница 144: ...odule see Figure D 3 has the following specifications Figure D 4 WS X4548 GB RJ45V E 48 Port Premium PoE 10 100 1000BASE T Switching Module To provide PoE with the 48 port PoE 10 100 1000BASE T switching module in a Catalyst 4500 E series switch you must have an PoE enabled power supply All power supplies support PoE except the 1000 W and 1400 W AC power supplies Note Auto MDIX is supported on thi...

Страница 145: ...BIT ETHERNET 17407 STATUS 4 1 2 3 4 5 5 6 6 7 7 8 8 9 9 1 0 1 0 1 1 1 2 1 1 1 2 WS X4148 RJ 4 PORT 10 100 B Table D 3 Switching Module LEDs LED Color State Description STATUS Indicates the results of a series of self tests and diagnostic tests performed by the switch Green All the tests pass Red A test other than an individual port test failed Orange System boot self test diagnostics running or th...

Страница 146: ...places the new module in the faulty state If the diagnostic test fails the system crashes which usually indicates that the new switching module has a problem and should be removed Caution To avoid erroneous failure messages allow at least 15 seconds for the system to re initialize and note the current configuration of all interfaces before you remove or insert another switching module When you hot...

Страница 147: ...cords table 2 5 2800 W power supplies power cord plugs 2 4 power cords table 2 7 A AC input power cords product numbers table 2 5 AC input power supplies description 1 25 environmental monitoring 1 29 figure 1 26 4 3 handling figure 4 6 installing 4 6 removing 4 4 replacing 4 6 source circuit requirements 2 3 troubleshooting 5 4 verifying operation 4 7 See also DC input power supplies ACTIVE LED d...

Страница 148: ...hes Catalyst 4506 switches Catalyst 4507 switches checklists site planning 2 11 commands show port D 8 components troubleshooting 5 4 to 5 19 connecting system ground 3 5 to 3 7 to console port C 2 console port connecting to C 2 description D 4 conventions warnings x D DC input power supplies connecting system ground 3 6 description 1 25 environmental monitoring 1 29 figure 1 27 4 4 handling figur...

Страница 149: ...ash code troubleshooting 5 3 front panel components D 3 FRUs AC input power supplies 4 4 to 4 8 DC input power supplies 4 8 to 4 13 fan assemblies 4 13 to 4 15 G Gigabit Ethernet See 1000BASE T See 1000BASE X GOOD LEDs checking 4 7 troubleshooting 5 4 verifying power supply status 4 13 grounding connecting systems 3 6 ground wire figure 4 10 H heat dissipation description table 2 3 supervisor engi...

Страница 150: ...atalyst 4506 E switches 1 5 local on Catalyst 4507 switches 1 9 1 13 remote on Catalyst 4503 E switches 1 2 remote on Catalyst 4506 E switches 1 5 remote on Catalyst 4507 switches 1 9 1 13 management port LED D 3 Media Access Control addresses See MAC addresses Mux buffers 4 15 5 7 O OUTPUT FAIL LED environmental monitoring 1 29 P packaging materials B 1 port status LEDs 5 9 D 7 POST LEDs C 3 powe...

Страница 151: ...6 E switches 1 6 Catalyst 4506 switches 1 10 1 14 console ports D 4 description 1 16 LEDs table 1 22 slot locations 1 2 1 5 1 9 1 13 specifications table A 14 Supervisor Engine V 10GE front panels figure 1 21 switching modules Catalyst 4503 E supported 1 3 Catalyst 4506 E supported 1 6 Catalyst 4507R supported 1 11 Catalyst 4510R supported 1 15 LEDs D 7 switch load indicators D 3 T TAC contacting ...

Страница 152: ...Index IN 6 Catalyst 4500 E Series Switches Installation Guide OL 13972 01 ...

Отзывы: