41
SET0503020
5.3.2 Installing option (Slot#2 or Slot#3)
Install according to the following procedures.
ANNT)
- The installation location and quantity have to indicate by the system administrator.
(1) Proceed to the net procedure according to the following procedures.
→ When the Base Unit state is “AC Power On, System Power On”. Proceed to procedure (2).
→ When the Base Unit state is “AC Power On, System Power Off” or “AC Power Off”.
Proceed to procedure (3).
(2) The system administrator makes the PCI card installable state.
(3) Remove the PCI cassette of installation slot.
See Appendix F.9.4 “
Removing PCI card (slot#2 and slot#3)
(4) Mount the PCI card in PCI cassette.
See Appendix F.9.3 “
Installing PCI card (slot#2 and slot#3)
(5) Install the PCI cassette into the IOUB.
→ Wait about 10 seconds
(6) When the Base Unit state is “AC Power Off”, turn on AC power then wait about a minute.
(7) Make sure that the Alarm indicator of the PCI cassette is not lit. (See “Figure 5.3.2”.)
Figure 5.3.2
(8) Install SPF+module if you have one.
See Appendix F.13 “
(9) Proceed to the next procedure according to the following procedures.
→ When the Base Unit state is “AC Power On, System Power On”.
Proceed to “
5.5 Preparation of handing over to the system administrator
→ When the Base Unit state is
“AC Power On, System Power Off”.
Proceed to “
Содержание C880 M5
Страница 18: ...18 SET0103040 1 3 4 Installation area Confirm installation area when 19 inch rack mounted Figure 1 3 4 ...
Страница 94: ...94 Appendix ...
Страница 97: ...97 Figure B 1 Distribution panel breaker characteristics ...
Страница 102: ...102 Figure D 3 3 When 1 AC Source Figure D 3 4 When 1 AC Source ...
Страница 105: ...105 Figure E 2 1 2 ...
Страница 108: ...108 Figure E 3 1 2 ...
Страница 112: ...112 Figure E 5 1 2 ...
Страница 119: ...119 Figure E 10 2 ...
Страница 120: ...120 APP0600000 Appendix F Handling the Units APP0601000 F 1 Unit location Figure F 1 1 Front Figure F 1 2 Rear ...
Страница 132: ...132 Figure F 7 1 2 3 Hold the groove of the Socket cover and it lift and remove it from the SB See Figure F 7 1 3 ...
Страница 134: ...134 Figure F 7 1 4 5 Tighten the heat sink screw in order number 1 2 3 4 and fix to SB See Figure F 7 1 5 ...
Страница 135: ...135 Figure F 7 1 5 ...
Страница 137: ...137 Figure F 8 1 2 Figure F 8 1 3 ...
Страница 142: ...142 Figure F 9 3 3 Figure F 9 3 4 ...
Страница 144: ...144 Figure F 10 1 3 ...
Страница 152: ...152 Figure F 13 1 1 Module MC 0JXEL1 Figure F 13 1 2 Module MC 0JCEK1 ...
Страница 156: ...156 APP0614000 F 14 Installing M 2 Flash Device See Figure F 14 Figure F 14 ...
Страница 163: ...163 APP0617000 F 17 Installing TPM See Figure F 17 Figure F 17 ...
Страница 165: ...165 Figure G 1 2 ...
Страница 171: ...171 APP0902000 I 2 Fibre Channel card Figure I 2 ...
Страница 172: ...172 APP0903000 I 3 SAS card SAS RAID controller card Figure I 3 ...
Страница 173: ...173 APP0904000 I 4 CNA card Figure I 4 ...
Страница 174: ...174 APP0905000 I 5 Infiniband HCA card Figure I 5 ...