Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
The following figure shows the ASR1006-PWR-DC power supply and components.
Figure 265: Cisco ASR 1006 Router DC Power Supply (ASR1006-PWR-DC)
DC power supply ground
studs
6
Fan
1
DC power supply captive
screw
7
DB-25 alarm connector*
2
DC power supply handle
8
Tie-wrap tab
3
On/Off (|/O) circuit
breaker switch
9
DC power supply
terminal block and plastic
cover
4
Power supply LEDs
10
Ground symbol
5
Cisco ASR 1000 Series Router Hardware Installation Guide
543
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing a DC Power Supply in Cisco ASR 1006 Router