Connecting Power to the Cisco ASR 1006 Router
The covers are an integral part of the safety design of the product. Do not operate the unit without the
covers installed. Statement 1077
Warning
When you install the unit, the ground connection must always be made first and disconnected last. Statement
1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
This section describes the procedure to connect AC input and DC input power to your Cisco ASR 1006 Router.
The DC power supply for the Cisco ASR 1006, ASR 1004, ASR 1002, and ASR 1013 routers operate at
individual specifications. The following table shows the common input ranges and circuit breaker requirements.
Table 48: Cisco ASR 1000 Series Router DC Power Supply System Input Requirements
AWG # Wire
Circuit Breaker
Amps
System Input Rating
(Amps)
Cisco ASR 1000
Series Router DC
Power Supply
Maximum
Minimum
Maximum
Minimum
Always AWG #6
wire
Always 50
40
Cisco ASR 1006
8
10
40
30
24
Cisco ASR 1004
10
12
30
20
16
Cisco ASR 1002
Always AWG #6
wire
Always 50
40
Cisco ASR 1013
Cisco ASR 1000 Series Router Hardware Installation Guide
165
Cisco ASR 1006 Router Overview and Installation
Connecting Power to the Cisco ASR 1006 Router
Содержание ASR 1001
Страница 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Страница 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Страница 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Страница 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...
Страница 698: ...Cisco ASR 1000 Series Router Hardware Installation Guide 664 MIBs Overview MIBs for the Cisco ASR 1001 Router ...