Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques 21
Installing Cards and Appliques
The ribbon cables from your FDDI applique are labeled as follows:
•
FDDI A through D for the first applique
•
FDDI E through H for the second applique
•
FDDI I through L for the third applique
•
FDDI M through P for the fourth applique
Connect the four applique ribbon cables to the C2FCIT card as follows.
Caution
To prevent twisting the ribbon cables and causing a possible short circuit, individually
route each cable (from the FDDI applique) under the main card cage through the space provided and
then up to the corresponding C2FCIT card connector.
Step 1
Connect the applique ribbon cable P3 A, E, I or M (the second cable from the left in
Figure 15) to the 26-pin connector labeled FDDI A, E, I, or M on the left front edge of the
C2FCIT card shown in Figure 14.
Step 2
Connect the applique ribbon cable P2 B, F, J, or N (the second cable from the right in
Figure 15) to the 26-pin connector labeled FDDI B, F, J, or N in Figure 14.
Step 3
Connect the applique ribbon cable P1 C, G, K, or O (the far-right cable in Figure 15) to the
26-pin connector labeled FDDI C, G, K, or O in Figure 14.
Step 4
Connect the applique ribbon cable P4 D, H, L, or P (the far-left cable in Figure 15) to the
far-right (16-pin) connector labeled FDDI D, H, L, or P in Figure 14.
Table 4
FDDI Applique Ribbon Cable and CSC-C2FCIT Connector Designations
Figure 14
Orientation of the FDDI Connectors on the CSC-C2FCIT Card
FDDI Ribbon
Cable
From
Connector
To CSC-C2FCIT
Connector
FDDI A, E, I, or M
P3
FDDI A, E, I, or M
FDDI B, F, J, or N
P2
FDDI B, F, J, or N
FDDI C, G, K, or O
P1
FDDI C, G, K, or O
FDDI D, H, L, or P
P4
FDDI D, H, L, or P
U32
Microcode
EPROM
Serial
PROM
U34
H1540a
FDDI A, E, I, M
FDDI B, F, J, N FDDI C, G, K, O
FDDI D, H, L, P