4-23
Cisco Aironet 1570 Series Outdoor Access Point Hardware Installation Guide
OL-32138-01
Chapter 4 Installing Other Components
Powering the Access Point
Figure 4-13
Cable Gland
Note
The cable gland can accept cables of diameter from 0.20 to 0.35 in. (0.51 to 0.89 cm).
Step 5
Insert a bare end of the DC power cable into the rounded end of the cable gland (see
pull approximately 6 inches of cable through the adapter.
Warning
When installing the DC power cable, ensure that cable gland and the rubber gasket are present and
installed properly, to avoid water leakage into the enclosure.
Step 6
Strip the DC cable jacket back by about 1 inch to expose the wires and then strip the insulation by about
0.5 inch (or 12 mm) from each wire.
Step 7
Push in the orange colored spring-loaded securing tabs and insert the wire (see
) all the way
into the two-position terminal block connector (Cisco Part Number 29-100226-01,
then release the tabs. Tug on the wire to ensure that it is properly secured.
Figure 4-14
Push in the securing tab, and wire, as the arrow shows
1
Thread end
2
Round end