VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
11
Fixed Trigger Shutter Mode
This is a mode to start exposure by inputting trigger signals, and to set its exposure time manually or with preset.
・
Set “TriggerSelectorAndActivation” to “FrameStartRisingEdge” or “FrameStartFallingEdge.”
・
Trigger cycle needs to be longer than the time for FVAL term (
≒
1/frame rate.)
・
Trigger cycle needs to be longer than the exposure time.
・
Trigger operation is CLK Sync HV Sync Reset.
・
More than 30µs of trigger pulse width can be input.
・
Maximum exposure time depends on ROI settings, “PixelFormat”, and link rate.
Effective Line
~ ~
Exposure Out
Trigger
FVAL
Video Out
LVAL
Effective Line
Image
Header
Idle
Stream data
Stream data
Idle
Idle
Exposure delay time (A)
Cxp Stream
Image
Header
~ ~
Readout time
Exposure time
Trigger input forbidden period
Exposure delay time (B)
Aegis Electronic Group, Inc.