VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
24
(2) High Level Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Sequence Control Stop
Sequence Control ReStart
Effective Line
Effective Line
Effective Line
①
To execute sequence operation during the trigger input is set to High level, please set SequencerActivation to
FrameBurstStartLevel.
・
To pause the trigger input in mid-flow, please set the trigger input to Low level.
(To finish the trigger input directly, please turn OFF sequence control.)
・
Sequence shall continuously operates if the trigger input is set to High level again at pause.
・
After completion of loop count of image output, the sequence operation will end and the operation will stop.
(3) Register Start
The sequence operation will start at the same timing as SequencerActivation is set to FrameBurstStartSoftware.
9.5
Index Mode
This mode is to specify the applying Index no. directly by IndexSelectorModeIndexNumber.
The Index parameter set specified by IndexSelectorModeIndexNumber shall be applied to camera per trigger
input.
Performance Chart
Applying param
Index #0
Applying param
Index #1
Applying param
Index #2
Applying param
Index #3
Applying param
Index #15
#0
#1
#0
#1
#15
Index Selector
RegisterModeIndexNumber
Shutter
Gain
Param #0
Shutter
Gain
Param #1
Shutter
Gain
Param #2
Shutter
Gain
Param #3
Shutter
Gain
Param #15
Sequence Index
Parameter Index Number
Combination of each Index
and parameter set