VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
21
9.1
Basic Operation
Please follow the procedures below when to use sequence control function.
①
AcquisitionControl --- TriggerSelectorAndActivation settings
To set the operation mode of the camera.
②
Sub-sampling and ROI settings
Please remain turn OFF SubsamplingMode. Please set ROI of ImageFormatControl to ROIQuickChangeOff.
These functions do not work at sequence control function.
③
Set the parameter table (SequenceerParameterSetSelector) for sequence
Please set ExposureTime and Gain of each parameter set.
④
Set ParameterIndexNumber for sequence and Index loop count
Set “IndexLoopCount”, “SequencerLoopCount”, and “ActiveIndexNumber”.
⑤
SequencerControl --- Settings for SequencerActivation.
To set the starting operation of sequence mode. If to set preferred [SequencerActivation], trigger waiting mode
shall be executed.
⑥
Sequence Control operation shall be executed when the trigger to operate sequence is input.
※
Note
・
Please decide link configuration beforehand when to set each functions.
・
The trigger input timing guideline at sequence control is the same as at normal mode.
・
When to set the settings for sequence, please turn OFF SequencerActivation once.
・
UseSetSave and UserSetDefault shall not be executed at SequencerMode. Please set them after turn on the
power. (UserSetSave and UserSetDefault can be executed at other settings for sequence except
SequencerMode.)
・
If the trigger is input, sequence shall start when the SequencerActivation is set to other than OFF. Please do not
input any triggers when to switch SequencerActivation.
・
Please refer to the maximum exposure time in 8.2 Exposure Settings for the exposure time for each parameter
settings.
・
At burst mode, the screen will hold the last picture of sequence control when finished sequence control.
・
When turn OFF SequencerActivation, the camera will return to the condition before sequence control.
9.2
Outline for Trigger Mode and Burst Mode Operation
This is a mode to specify Index transition flow in advance. (The repeating count for each Index, the number of the Index to be
used, and the number of Loop can be set.)
・
Trigger Mode
Whenever an external trigger is input, the repeat count of Index shall be sum up, and the parameter set shall be applied to
the camera.
・
Burst Mode
This mode shall be executed by equivalent of free run at internal sync. mode. Sequence shall be started by trigger, repeat
count of Index will be sum up automatically by internal trigger, and the specified parameter set shall be applied to the
camera.
Aegis Electronic Group, Inc.