Preliminary Product Information
This document contains information for a new product.
Cirrus Logic reserves the right to modify this product without notice.
1
Copyright
Cirrus Logic, Inc. 2001
(All Rights Reserved)
P.O. Box 17847, Austin, Texas 78760
(512) 445 7222 FAX: (512) 445 7581
http://www.cirrus.com
CS5460A
Single Phase Bi-Directional Power/Energy IC
Features
!
Energy Data Linearity: ±0.1% of Reading
over 1000:1 Dynamic Range.
!
On-Chip Functions: (Real) Energy, I
∗
V,
I
RMS
and V
RMS
, Energy-to-Pulse Conversion
!
Smart “Auto-Boot” Mode from Serial
EEPROM Enables Use without MCU.
!
AC or DC System Calibration
!
Mechanical Counter/Stepper Motor Driver
!
Meets Accuracy Spec for IEC 687/1036, JIS
!
Power Consumption <12 mW
!
Interface Optimized for Shunt Sensor
!
V vs. I Phase Compensation
!
Ground-Referenced Signals with Single
Supply
!
On-chip 2.5 V Reference (MAX 60 ppm/°C
drift)
!
Simple Three-Wire Digital Serial Interface
!
Watch Dog Timer
!
Power Supply Monitor
!
Power Supply Configurations
VA+ = +5 V; VA- = 0 V; VD+ = +3.3 V to +5 V
Description
The CS5460A is a highly integrated
∆Σ
Analog-to-Digital
Converter (ADC) which combines two
∆Σ
ADCs, high
speed power calculation functions, and a serial interface
on a single chip. It is designed to accurately measure
and calculate: Real (True) Energy, Instantaneous Pow-
er, I
RMS
, and V
RMS
for single phase 2- or 3-wire power
metering applications. The CS5460A interfaces to a
low-cost shunt resistor or transformer to measure cur-
rent, and resistive divider or potential transformer to
measure voltage. The CS5460A features a bi-directional
serial interface for communication with a micro-control-
ler and a pulse output engine for which the average
pulse frequency is proportional to the real power.
CS5460A has on-chip functionality to facilitate AC or DC
system-level calibration.
The “Auto-Boot” feature allows the CS5460A to function
‘stand-alone’ and to initialize itself on system power-up.
In Auto-Boot Mode, the CS5460A reads the calibration
data and start-up instructions from an external EE-
PROM. In this mode, the CS5460A can operate without
a microcontroller, in order to lower the total bill-of-mate-
rials cost, when the meter is intended for use in
high-volume/residential metering applications.
ORDERING INFORMATION:
CS5460A-BS -40
°
C to +85
°
C
24-pin SSOP
PGA
x10,x50
VA+
VD+
IIN+
IIN-
VIN+
VIN-
VREFIN
VREFOUT
VA-
XIN
XOUT CPUCLK
DGND
CS
SDO
SDI
SCLK
INT
EOUT
Digital
Filter
High Pass
Filter
Voltage
Reference
System
Clock
/K
Clock
Generator
Serial
Interface
Power
Calculation
Engine
(Energy
I * V
I
,V
)
RMS
RMS
Energy-to-
Pulse
Converter
Power
Monitor
PFMON
x1
x10
4
Order
πΓ
Modulator
th
RESET
Digital
Filter
Calibration
SRAM
EDIR
High Pass
Filter
2
Order
πΓ
Modulator
nd
Watch Dog
Timer
MODE
Control /