The
sequence
is the number of hop frequencies in the hop pattern in the
radio in the SEM. The default is 75 for US/ETSI operation. All other
frequency bands, as set in the radio by the
pe
command, have 25 frequencies
in their hop patterns. This value is entered as a decimal number. The
sequence needs to be modified only if modified in the radio in the SEM.
remote Displays the serial numbers of the radios in the SEMs that are currently
registered with the SEM.
sync These commands set the operation of the synchronization signal used in co-
located SEM networks. The default mode is the sync OFF. Sync is enabled
by selecting a synchronization method.
ether
and
wire
are mutually
exclusive commands and set the synchronization to occur over the Ethernet
or over the RS-485 signal lines. When sync is enabled, the default mode of
the SEM is slave. One SEM must be configured as the sync master. If sync
has been enabled, the slave SEMs will listen for a sync signal from the
master. If no sync is heard, a slave SEM will make itself a master and
provide a sync signal. This is called the master backup override mode.
override
toggles the master backup override on and off. In standalone SEM
installations, synchronization is not required and should be left disabled.
remote Displays the serial numbers of the radios in the SEMs that are currently
registered with the master SEM.