40
Wallbox eNext User Manual
A
Blinking red errors
Nº of
blinks
Error
Description
Solution
3
Low voltage
No voltage detected in
the power circuit.
Make sure all protections are armed.
5
Electric
protection
The electric protections
of the unit are tripped.
Rearm the protections. If you have any
question, contact technical support.
6
Current leak
A current leakage has
been detected.
Rearm the protections. If you have any
question, contact technical support.
11
Connector
lock
The connector lock has
failed.
Try repeating the operation. If the
error persists, contact technical
support.
12
Welded
contact
An internal short circuit
has been detected.
Unplug the vehicle, restart the unit
and try again. If the error persists,
contact technical support.
14
Damaged
cable
The cable plugged to
the Charge point is
damaged.
Try using another cable. If the error
persists, contact technical support.
15
Negative
PWM
Invalid communication
response from the EV.
Unplug the cable and wait until the
LED beacons turn green to plug it
again. If the error persists, contact
technical support.
16
E Status
Communication error
between the vehicle and
the equipment.
Try using another cable. If the error
persists, contact technical support.
17
D Status
Ventilation system is
needed because of EV
request.
Please contact technical support.
18
Maintenance
required
(Relays)
Some internal
components need
maintenance.
Please contact technical support.