1.2.
【E1】:When memory device damaged or read or write had program, all window display
will be off and all output will be stop and show【E1】on TIME window, show【EEPROM
ERROR】 on dot-matrix window.
1.2.1.Solution:Replace the console PCB.
1.3.
【E2】:IF incline had some problems when initial, incline can not reach the right
position, will show 『
ELEVATION ERROR
ELEVATION ERROR
ELEVATION ERROR
ELEVATION ERROR
PRESS STOP TO BYPASS
PRESS STOP TO BYPASS
PRESS STOP TO BYPASS
PRESS STOP TO BYPASS
』on dot-matrix window,
press STOP to bypass the signal but incline function can not be use, if incline had
some problems when during workout, the INCLINE window will show 【E2】but other
function are normal to use.
※If this is a all new product that just finished assemble, there are more possibly in
assemble problems, maybe connect wire not well or wire damaged while assemble.
1.3.1.Steps illustrate:
Step
illustrate
Auxiliary Photo
1
Open the motor cover then switch OFF the
AC power source and wait 10 seconds then
ON the AC power.
2
Check the pilot lamps LED4 & LED5 on
interface PCB before show 【E2】.
The LED4 or LED5 light up before show E2?
Yes:Next step.
No:Check console wire connect well.
Refer to:
2.1『Interface PCB』
2.2『Console Wire』
OFF
ON