09.01.g. diagnostics
- fan time: to determine for how many minutes after the latest
dispensing cycle the powder suction fan will remain active;
- beep time: beep time active at the end of each machine function;
- number of decimals: to determine how many decimals are
considered in the comparison between the selection price and the
credit you have inserted;
- language: to display the messages in one of the three languages
made available;
- display colour; to select the display aspect you wish;
- first installation: used to make sure that the water circuit will be
filled in at the next power on; if the value is zero, the machine
will perform the cycle just as for 08.02 at the next power on;
- deinstallation: to empty water circuits automatically:
- detach the water supply and press “10”;
- following the display’s messages, verify that the drip tray and
the grounds container are empty an press key “10”;
- insert an extension into the drain tap of the pressure boiler
(see 05.11. and 13.20.), remove the plug from the outlet hose
of the air break (see 05.10. and 13.20.), put them close to a
bucket and press “10”;
- open the pressure boiler tap and press “10”;
- the display shows:
- remove the tube, close the pressure boiler tap and reinsert the
drain plug of the air break when the display shows:
at the end of the uninstall cycle, the pressure boiler water
temperatures will be set to zero and the machine will be set to
“FIRST INSTALLATION=0”;
- to enable the summer time function (from the last Sunday in
March to last Sunday in October, the set time is automatically
increased by one);
- if enabled, the operator can reset the water filter decounter by
pressing the “PROG” key; (see 05.14.);
press key “2” to access diagnostics and to enable the machine to
display (keys “4” and “5”) the standby message and the pressure
boiler water temperature, alternatively;
press “2” once again to display the voltage value intended to
supply devices at 24 V dc;
activ. H2o filter
Reset 0=no 0
ENABLE DISPLAY
TEMPERA. 1=YES N
VOLTAGE
volt 00.0
Summer Time
1= yes N
MAN1010119 rel. 01 dated 30.01.2014
page no. 31 of 52 page
www.rheavendors.com tel: 0039 02 966 551 fax: 0039 02 96 55 086 e mail: [email protected]
rheavendors group's sole property
cino eC PRO by
display color
00
first installat.
0=first N
fan time
min. NN
Beep time
0.0
decimal number
N
language :
english
Deinstallation
10=START
open boiler tap
P10= START
deinstallation
in progress..
END
Close boiler tap
connect boiler
tube 10 = >
driptray
empty? 10=START
remove coffee
grounds 10=START