3.4 Remote control pairing
To activate the pairing function, press and release the “REMOTE SET” button on
the control unit. Then a red LED will fl ash on the control unit. While the LED is
fl ashing, press for at least 3 seconds one of the buttons of the remote control to
pair it.
Multiple control units can be paired and used with a single remote control.
Multiple remote controls can be paired and used with the same control unit.
Pairing must not be activated during the track memorization cycle.
To unpair the remote control from the control unit, press and release the
‘REMOTE SET’ button, after which the red LED will fl ash. Press the ‘REMOTE
SET’ button again and keep it pressed until the led stops fl ashing. When the
button is released, the red LED will fl ash 5 times to confi rm the unpairing.
The unpairing of a remote control completely eliminates its association with any
control unit. In order to use the remote control, it will be necessary to pair it again
using the standard procedure.
3.5 Wiring of the control unit switch
The NO switch is a simple, normally open contact controlled by control unit.
No voltage output is supplied from the switch terminals.
The switch can control equipment with a nominal voltage of between 0 and 48V and a maximum
current of 2A.
Wiring for control via the switch must be performed by specialized personnel according to the
wiring diagram supplied.
3.6 Checks
Check that each door moves correctly.
Check that the system is effective in avoiding crushing, by introducing an object between the cabinet side and the closing door.
Perform this checks in order to avoid any risk, damage or injury due to possible faults or malfunctioning of the system.
REMOTE
SET
00:00:03
FREQUENCY: 433,92 MHZ
MAX POWER: 1 mW
DEVICE = 0 - 48V
MAX 2A
SWITCH
N/O
SOURCE
DEVICE
DEVICE
DEVICE
0 - 48
N/O
SWITCH
O
I
SOURCE
DEVICE
DEVICE
0 - 48V
MAX 2A
N/O
SWITCH
4.1 Door opening
The door opening command can be given by slightly pushing on the door or by using the remote control.
Push the door a few millimetres in its opening direction and the system will automatically detect the displacement and operate the motor until
the door reaches its open position.
4. Use instructions
English
99
Assembly Instructions
Cinetto
PS40 & B-moved.
Содержание B-MOVED PS40
Страница 15: ...15 Assembly Instructions Cinetto PS40...
Страница 29: ...29 Assembly Instructions Cinetto PS40...
Страница 31: ...Right blue Left red Left red Left red Right blue Right blue 3 4 31 Assembly Instructions Cinetto PS40...
Страница 32: ...Left red Right blue Left red Right blue 5 32...
Страница 37: ...6 7 8 37 Assembly Instructions Cinetto PS40...
Страница 40: ...S d1 WA WA 2 X S 214 S X 2 MIN X 2 MIN d Right 11 8 mm 40...
Страница 45: ...35 17 35 25 70 PS40 1 15 45 Assembly Instructions Cinetto PS40...
Страница 46: ...35 17 35 25 70 PS40 2 15 46...
Страница 50: ...50...
Страница 53: ...3 4 3 mm 53 Assembly Instructions Cinetto PS40...
Страница 55: ...55 Assembly Instructions Cinetto PS40...
Страница 71: ...3 4 71 Assembly Instructions Cinetto PS40 B moved...
Страница 72: ...5 6 72...
Страница 75: ...10 75 Assembly Instructions Cinetto PS40 B moved...
Страница 82: ...Connessione cavi Cable connection Connexion des c bles Kabelbaum Conexi n de los cables 82...
Страница 84: ...1 4 REMOTE CONTROL CONFIGURATION 92 97 102 107 112 CONFIGURATION E E 84...
Страница 117: ...117 Assembly Instructions Cinetto PS40 B moved...
Страница 118: ...118...
Страница 119: ...119 Assembly Instructions Cinetto PS40 B moved...