Troubleshooting 6-6 Manual 0-5280
TRANSARC 170i
DIODE Testing
Multimeter Lead Placement
Ohms
DIODE V7 & V7-1
Positive meter lead to testpoint 11
Negative meter lead to testpoint 12
0.2 – 0.8 VDC
DIODE T14, T15, T18
Positive meter lead to testpoint 13
Negative meter lead to testpoint 14
0.2 – 0.8 VDC
DIODE T16, T17, T19
Positive meter lead to testpoint 15
Negative meter lead to testpoint 16
0.2 – 0.8 VDC
Table 6-6: Diodes, Multimeter set to measure Diode Voltage
6.08 Check main input rectifier
Art # A-11815
Input Rectifier Testing
Multimeter Lead Placement
Diode Voltage
AC1 to DC+
Positive meter lead to 17
Negative meter lead to testpoint 18
0.2 – 0.8 VDC
AC2 to DC+
Positive meter lead to 19
Negative meter lead to testpoint 18
0.2 – 0.8 VDC
AC1 to DC-
Positive meter lead to testpoint 17
Negative meter lead to testpoint 20
0.2 – 0.8 VDC
AC2 to DC-
Positive meter lead to testpoint 19
Negative meter lead to testpoint 20
0.2 – 0.8 VDC
Table 6-7: Input Rectifier, Multimeter set to measure Diode Voltage