![CIGWELD TRANSarc 130i Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/cigweld/transarc-130i/transarc-130i_service-manual_2607027043.webp)
TRANSARC 170i
Manual 0-5280 6-1
Troubleshooting
6.01 Basic Troubleshooting-Power Source Faults
The following table is a guide for analyzing problems and making repairs to the Power Source.
Fault
Possible Cause
Remedy
1 There is no weld output and
all front panel displays are
off
A The main Power Switch is
set to OFF
A Set main Power Switch to ON
B Line fuse is blown
B Replace Line fuse
C The main Power Switch is
faulty
C Replace main Power Switch
D Faulty Power Inverter board
D Replace Power Inverter board
E Faulty Control board
E Replace Control board
F Faulty Display board
F Replace Display board
2 There is no weld output and
all front panel displays are
off or flickering on & off
A The internal protection circuit
to shut the unit down if the
mains supply voltage is too
high has operated
A Check to see if mains supply voltage
is <274VAC. A generator with poor
voltage regulation may cause a
supply voltage in excess of 274VAC.
Connect Power Source to a supply
voltage <274VAC.
3 There is no weld output and
the yellow over temperature
light is on
A Unit has overheated
A Allow unit to cool with fan running
until over temperature light
extinguishes
B Airflow inlet or outlet ducts
are blocked
B Remove blockages from airflow
ducts
C Fan does not operate
C Replace fan. Check fan wiring header
is plugged securely into Control
board. Check fan wiring is not
damaged
4 Mode switch does not
change welding mode
A Faulty Display board
A Replace Display board
5 The weld output do not
operate when the torch
trigger switch is depressed
A Internal wiring fault
A Check continuity of internal wiring
from8 pin control socket through to
boards
B Over temperature light is on
B Allow unit to cool
C Trigger wires shorted to weld
voltage inside TIG torch
C Repair trigger wires in torch
D Trigger wires or torch switch
faulty
D Check & Repair
E Faulty Power Inverter board
E Replace Power Inverter board
F Faulty Control board
F Replace Control board
G Faulty Display board
G Replace Display board
SECTION 6:
TROUBLESHOOTING
Содержание TRANSarc 130i
Страница 6: ......
Страница 18: ...INTRODUCTION 2 2 Manual 0 5280 transarc 170i Notes...
Страница 42: ...Theory of Operation 5 2 Manual 0 5280 TRANSARC 170i Notes...
Страница 68: ...TRANSARC 170i DISASSEMBLY PROCEDURE 7 8 Manual 0 5280 Notes...
Страница 76: ...ASSEMBLY PROCEDURES 8 8 Manual 5280 TRANSARC 170i Notes...
Страница 80: ...TRANSARC 170i KEY SPARE PARTS 9 4 Manual 0 5280 Notes...