Troubleshooting 6-4 Manual 0-5280
TRANSARC 170i
6.06 Preliminary DC Bus measurement of the main inverter board
!
WARNING
Check DC bus voltage has discharged to less than 5VDC before servicing. Ensure the mains supply
plug is disconnected from receptacle.
Art # A-11813
DC Bus Testing
Multimeter Lead Placement
Voltage with Supply voltage OFF
Upper capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 2
0 VDC
Lower capacitor bank
Positive meter lead to testpoint 2
Negative meter lead to testpoint 3
0 VDC
Table 6-2: DC BUS, Multimeter set to measure DC volts