Auto-negotiation and MDI/MDIX auto-sensing 

 

Built-in layer-2 switch 

 

Advanced data features such as VLAN tag manipulation, classification, and filtering 

2.2.2. Video 

 

The M-97RG2 supports video service delivered in form of data (by multicast or unicast). 

 

M-97RG2 supports IGMP snooping function. When IGMP snooping is enabled, M-97RG2 monitors 
the member joining and leaving activities at the Ethernet/WLAN service port, and then selectively 
delivers the multicast streams. 

2.3.

 

Specifications

 

Gateway physical, electrical, MoCa2.5, and environmental specifications and compliance information 
are listed in the following tables.

 

 
Table 1 Physical specification   

Dimensions

 

240mm(bracket inclusive) x170mm x72mm (H x W x D)   

 

Weight

 

1

KG

 

MoCa2.5 interface

 

MOCA WAN frequency range:1125MHz~1675MHz   

TX Power: -1~+7dBm,t3dBm 

 

Ethernet interface

 

RJ-45

 connector

 

 
 
Table 2 Electrical specification 

Input Power

 

+12V 

DC Power input

 

Power Supply

 

2-PIN AC Power input

 

Power 
Consumption

 

<18W 

 
 
Table 3 Environmental specification   

Temperature

 

0° C ~ 40° C 

Humidity

 

5% ~ 95%

 relative humidity

 

 

Содержание ONT M-97RG2

Страница 1: ...M 97RG2 Hardware Installation Manual ONT M 97RG2 Hardware Installation Manual Mar 2021 Rev 2...

Страница 2: ...pecifications products and products names are subject to change without notice Performance figures and data quoted in this document are typical and must be specifically confirmed in writing by CIG bef...

Страница 3: ...2 2 1 Data 8 2 2 2 Video 9 2 3 Specifications 9 3 Hardware Operation 10 3 1 Environmental Requirements 10 3 2 Power Requirements 10 3 3 Mountings the Gateway 10 3 4 Uninstall the Gateway 11 4 Service...

Страница 4: ...y Connecting the Gateway to the MoCa2 5 network Auto negotiation and MDI MDIX auto sensing Built in layer 2 switch Advanced data features such as VLAN tag manipulation classification and filtering The...

Страница 5: ...ice without authorization Abide by local laws and regulations and respect the legal rights of others when using the device 1 2 Environmental Requirements Install the device in a well ventilated place...

Страница 6: ...may become damaged Damaged cables can cause a device failure Do not use cables that are damaged or have deteriorated 1 4 Instructions for Cleaning Before cleaning the device stop operation of the dev...

Страница 7: ...ng as well as all the safety instructions outlined in this manual when using this product Once this product is installed and used it is the responsibility of the user to know and understand how to saf...

Страница 8: ...LAN1 LAN2 LAN3 LAN4 RJ 45 10 100 1000 Base T Ethernet Interface or 10 100 fast Ethernet Interface connecting to PC or Set Top Box MoCa2 5 Connection established with MOCA client ON OFF Power switch on...

Страница 9: ...e port and then selectively delivers the multicast streams 2 3 Specifications Gateway physical electrical MoCa2 5 and environmental specifications and compliance information are listed in the followin...

Страница 10: ...ther disasters 3 3 Mountings the Gateway The device supports two installation methods Installed on the wall and installed on the desktop Installing the Gateway on the Wall 1 Locate a safe and accessib...

Страница 11: ...ut of electricity cable into a live AC outlet 3 Verify that the power PWR LED on the Gateway is lit green indicating that local power is on and voltage is good 4 2 Connecting Ethernet Interface 1 Loca...

Страница 12: ...sioned in the network If services must be verified at the time of installation refer to Section for additional instructions 5 2 Activating the Gateway Once the Gateway installation is complete follow...

Страница 13: ...3 Verifying Services Follow local practices to connect to each active service port in the Gateway to confirm service activation 1 If Ethernet service is included in this installation confirm that dat...

Страница 14: ...and transfer Off Not active 6 MOCA Green Solid Connection established with MOCA client with no traffic running Green Flash Slow Establishing connection with MOCA client Green Flashing Fast Connection...

Страница 15: ...the WLAN service is started This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must...

Страница 16: ...used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmi...

Страница 17: ...ibility EMC Part 4 testing and measurement techniques section 2 electrostatic discharge immunity test EN 61000 4 3 2006 A1 2008 Electromagnetic Compatibility EMC Part 4 testing and measurement techniq...

Страница 18: ...ours a day 7 days a week To contact the CIG technical assistance center use one of the following methods Telephone 400 157 7899 Email support cambridgeig com When you contact CIG please have the follo...

Страница 19: ...ts contact your local sales representative or contact CIG at the address telephone fax number or e mail address Address 5 F Building 8 2388 ChenHang Road MinHang District Shanghai 201114 China Phone 8...

Отзывы: