5 - PHYSICAL AND ELECTRICAL DATA FOR THE UNITS
5.1 - Physical data LD 602R - 3500R
AQUACIAT
POWER™
LD
0602R 0650R 0750R 0900R 1100R 1200R 1350R 1400R 1600R 1750R
Sound levels
Unit + High temperature option/Nominal high performance
Sound power
(1)
dB(A)
91,0
91,5
91,5
92,0
92,0
93,0
93,0
93,5
93,5
94,0
Sound pressure at 10 m
(2)
dB(A)
58,5
59,5
59,5
60,0
60,0
60,5
60,5
61,0
61,5
61,5
Standard unit
Sound power
(1)
dB(A)
88,5
89,0
89,0
89,5
89,5
90,5
90,5
91,0
91,0
91,5
Sound pressure at 10 m
(2)
dB(A)
56,5
57,0
57,0
57,5
57,5
58,5
58,5
59,0
58,5
59,5
Unit + Very Low Noise option
Sound power
(1)
dB(A)
85,5
85,5
85,5
86,5
86,5
87,5
87,5
88,0
88,0
88,5
Sound pressure at 10 m
(2)
dB(A)
53,0
53,5
53,5
54,5
54,5
55,5
55,5
55,5
56,0
56,0
Unit + Ultra Low Noise option
Sound power
(1)
dB(A)
83,5
83,5
83,5
84,5
84,5
85,5
85,5
86,0
86,0
86,5
Sound pressure at 10 m
(2)
dB(A)
51,5
51,5
51,5
52,5
52,5
53,5
53,5
53,5
53,5
54,5
Dimensions
Standard unit
Length
mm
2410 2410 2410 2410 2410 3604 3604 3604 3604 4798
Width
mm
2253 2253 2253 2253 2253 2253 2253 2253 2253 2253
Height
mm
2324 2324 2324 2324 2324 2324 2324 2324 2324 2324
Unit + water buffer tank module option
Length
mm
3604 3604 3604 3604 3604 4798 4798 4798 4798 5992
Operating weight
(3)
Standard unit
kg
1349 1397 1397 1521 1556 1995 2049 2211 2269 2697
Unit + Ultra Low Noise option
kg
1453 1501 1501 1656 1690 2153 2208 2394 2452 2904
Unit + Ultra Low Noise + HP dual-pump hydraulic module option
kg
1588 1636 1636 1791 1837 2302 2403 2589 2646 3138
Unit + Ultra Low Noise + HP dual-pump hydraulic Buffer
tank module option
kg
2571 2619 2619 2774 2819 3288 3389 3575 3632 4131
Compressors
Hermetic Scroll 48.3 r/s
Circuit A
1
1
1
2
2
2
2
3
3
3
Circuit B
2
2
2
2
2
3
3
3
3
4
Number of power stages
3
3
3
4
4
5
5
6
6
7
Unit PED category
III
III
III
III
III
III
III
III
III
IV
Refrigerant
(3)
R-32 / A2L/ GWP= 675 in accordance with ARI4
Circuit A
kg
6,1
9,3
9,3
10,9
11,3
11,9
12,7
17,3
18,0
18,3
tCO
2
e
4,1
6,3
6,3
7,4
7,6
8,0
8,6
11,7
12,2
12,4
Circuit B
kg
10,9
10,9
10,9
10,9
11,3
16,7
17,5
17,3
18,0
21,9
tCO
2
e
7,4
7,4
7,4
7,4
7,6
11,3
11,8
11,7
12,2
14,8
Oil
Circuit A
l
6,6
6,6
6,6
13,2
13,2
13,2
13,2
19,8
19,8
19,8
Circuit B
l
13,2
13,2
13,2
13,2
13,2
19,8
19,8
19,8
19,8
26,4
Capacity control
Connect’Touch
Minimum capacity
%
33
33
25
25
25
20
20
17
17
14
Condenser
All-aluminium micro-channel coils (MCHE)
Fans
Axial with rotating impeller
Standard unit
Quantity
3
4
4
4
4
5
5
6
6
7
Maximum total air flow
l/s
11790 15720 15720 15720 15720 19650 19650 23580 23580 27510
Maximum rotation speed
r/s
12
12
12
12
12
12
12
12
12
12
Evaporator
Dual-circuit plate heat exchanger
Water volume
l
15
15
15
19
27
27
35
44
44
44
Max. water-side operating pressure without hydraulic module
kPa
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Hydraulic module (option)
Pump, Victaulic screen filter, relief valve, water and air vent valve,
pressure sensors
Pump
Centrifugal pump, monocell, 48.3 r/s, low- or high-pressure (as
required), single or dual (as required)
Expansion tank volume (option)
l
50
50
50
50
50
80
80
80
80
80
Buffer tank volume (optional)
l
550
550
550
550
550
550
550
550
550
550
Max. water-side operating pressure with hydraulic module
kPa
400
400
400
400
400
400
400
400
400
400
Water connections with or without hydraulic module
Victaulic
®
type
Connections
inches
3
3
3
3
3
4
4
4
4
4
External diameter
mm
88,9
88,9
88,9
88,9
88,9 114,3 114,3 114,3 114,3 114,3
Casing paint colour
Colour code RAL 7035 & 7024
(1) In dB ref=10
-12
W, (A) weighting. Declared dual-number noise emission value in accordance with ISO 4871 with an uncertainty of +/-3 dB(A). Measured in accordance
with ISO 9614-1 and certified by Eurovent.
(2) In dB ref 20 µPa, (A) weighting. Declared dual-number noise emission value in accordance with ISO 4871 with an uncertainty of +/-3 dB(A). For information, calculated
from the sound power Lw(A).
(3) Values are guidelines only. Refer to the unit name plate.
AQUACIAT
POWER
™ LD/ILD
EN-10