RECEIVER FUNCTION SELECTORS
Symbol
Function
SW1
Position 1 = MW Barrier Alignment
Position 2 = MW Barrier parameter Acquisition (Channel, Field Values,
masking and sensitivity threshold acquisition. Indication of
alignment quality)
Position 3 = MW Barrier Walk Test, Masking and sensitivity threshold
acquisition, verification of alignment quality
Position 4 = Doppler sensor Walk Test and Doppler sensitivity
threshold acquisition (Rx Column)
Position 5 = Doppler sensor Walk Test and Doppler sensitivity
threshold acquisition (Tx Column)
Position 6 = NOT Active
Position 7 = NOT Active
Position 8 = Barrier number Read/Write
Position 9 =
Set scenario “AND with 2 technology filter”
Position A = Set scenario “AND with priority filter”
Position B = Set scenario “AND”
Position C =
Set scenario “AND with Anti-climb”
Position D =
Set scenario “AND with Anti-creep”
Position E =
Set scenario “AND with Anti-creep + Anti-climb”
Position F = Set scenario “OR”
Position 0 =
Set scenario “AND with: 2 tech priority filters”
SELECTORS TO SET WORKING PARAMETERS OF RECEIVER
Symbol
Function
SW4
Control of anti-
masking sensitivity (“0” = low sensitivity, “F” = High
sensit
ivity, Default = “2”)
SW5
Control of intrusion sensitivity (“0” = Low sensitivity, “F” = High
sensitivity, Default = “7”)
10.1.3
IR Transmitter and Receiver Circuit
TERMINAL BLOCK TX
TERMINAL BLOCK RX
Mors
Symbol
Function
Mors
Symbol
Function
1 Tx
+
+ Power
1 Rx
+
+ Power
2 Tx
-
- Power
2 Rx
-
- Power
3 Tx
COM
Tamper
3 Rx
COM
Signal Alarm
4 Tx
NC
Tamper
4 Rx
NC
Signal Alarm
5 Tx
Synch
5 Rx
NO
Signal Alarm
6 Rx
COM
Signal EDC
7 Rx
NC
Signal EDC
8 Rx
COM
Tamper
9 Rx
NC
Tamper