PYTHAGORAS 3
CONNECTOR J2 RECEIVER
Pin
Symbol
Function
1
GND
Ground for Microwave Detector a
2
DET
Connection for Microwave Detector
3
GND
Ground for Microwave Detector
CONNECTOR J3 RECEIVER
Pin
Symbol
Function
1-2-3-5-8-10-11-13-
15-16
N.C.
Not used
4
GND
Ground
6
+13,8
Power supply (13,8 V
)
7
GND
Ground
9
0,2V
Received Signal 200 mVpp
12
+5V
Internal power supply voltage (5 V
)
14
VRAG
Automatic Gain Control (AGC) voltage
CONNECTOR J4 RECEIVER
Pin
Symbol
Function
1
GND
Ground Connection to Tamper switch
2
ING
Tamper switch input
3
GND
Ground Connection to Tamper switch
JUMPERS RECEIVER
Symbol
Function
Default
Jp1
Exclusion of Alarm, Tamper and Fault led (D6, D5, D4)
ON
Jp2
Line Termination
OFF
RECEIVER LEDS
Symbol
Indication
Default
D4
Fault
+ Alignment
ON
D5
Alignment
ON
D6
Alarm + Alignment
ON
FUNCTION ACTIVATION PUSH BUTTONS
Symbol
Function
S1
-Activation of recovery and acquisition of values in Alignment phase
(with SW1 in position 1)
- Acquisition of Channel, Field values and indication of Alignment
quality (with SW1 in position 2)
- Activation of Alignment quality indication and Acquisition of Sens
and Mask parameters (with SW1 in position 3)
- Acquisition of Doppler sensitivity (with SW1 in position 4 and 5)
- Acquisition of Barrier Number (with SW1 in position 8)
RECEIVER TEST POINTS
Symbol
Function
Tp 3
Field signal measurement 200 mVpp (Oscilloscope)
Tp 4
Automatic Gain Control Voltage Measurement (V RAG)
Tp 10
Ground for measuring instrument
Содержание PYTHAGORAS3