PYTHAGORAS 3
9.2 Number of Zones
When planning protection of a closed perimeter using volumetric barriers, as well as the normal
considerations relating to the subdivision of the system into a specific number of zones to suit
the management of the systems, it is also necessary to remember that it is preferable to install
an even number of zones for this type of technology. This is because in a closed perimeter
created by an odd number of zones it would be necessary to have an overlap/crossover
between a transmitter and a receiver which could cause mutual interference.
In figure 2a) the corner between the two TX and Rx is correct, but the two heads are very close
and the transmitter that corresponds to the receiver positioned on this corner is a very long way
away. In figure 2d) the two TX and RX heads create a corner greater than 90° and are therefore
not correct because the two heads are very close together.
CORRECT
CORRECT
INCORRECT
INCORRECT
CORRECT
CORRECT
Fig.2a
Fig.2f
Fig.2e
Fig.2d
Fig.2c
Fig.2b