CORAL-PLUS
RECEIVER TEST POINTS
Symbol
Function
Tp 3
Measure of field signal 200 mVpp (Oscilloscope)
Tp 4
Measure of the Automatic Gain Regulator Voltage Value (V RAG)
Tp 10
Ground reference for instruments
RECEIVER FUNCTION SELECTION SWITCH
Symbol
Function
SW1
Position 1 = Barrier Alignment
Position 2 = Acquisition of: Channel Number, Value of Received Field
and indication of Alignment Quality
Position 3 = Acquisition and section parameters (thresholds
Read/write)
Position 4 = Normal Functionality, Walk-Test and indication of
alignment quality
RECEIVER SWITCHES TO SET THE WORKING-PARAMETERS
Symbol
Function
SW4
Regulation of the anti-
masking control sensitivity (“0” = Low sensitivity,
“F” = High sensitivity, Default “8”)
SW5
Barrier Sensiti
vity regulation (“0” = Low sensitivity, F High Sensitivity,
Default “7”)
SW6
Type of answer of the barrier intrusion
(Default = “5”)
0 = Very High Decrease of Sensitivity
Use this for targets that are very big
or very close to the Tx and
Rx heads.
(Big birds, cats that can jump near the heads ect.)
1 =High Decrease of Sensitivity
T
argets that are big or very close to the
Tx and Rx
heads
2 = Medium Decrease of Sensibility
Targets that are big
or very near to the heads
Tx and Rx
3 = Decrease of Sensitivity
Targets that are big or very near to the heads Tx and Rx
4 = Decrease of Sensitivity
Equal for every target
5 = Standard
6 = Increase of Sensitivity
Equal for every target
7 = Increase of Sensitivity
for small targets
(crawling/rolling intruder)
8 = Medium increase of sensitivity
for small targets
9 = High increase of Sensitivity
for small targets
RECEIVER NUMBER OF BARRIER SWITCHES SW2 SW3
N°
Symbol
Function
2
SW2
Barrier Number selector (units column)
3
SW3
Barrier Number selector (tens column)
Содержание CORAL-PLUS