2.9 Wall installation
Besides perimeter protection, another possible application for MW barriers is wall installation for
protection of windows, doors, front gates, driveways to villas, warehouses, and in general all
those kind of facilities or facades for which that kind of protection is suitable.
The facade/wall becomes the working plane for the barrier: take care to have just one
working plane
.
Take care of the following before installation:
Use the right bracket according to distance
Choose the right height according to kind of application (protection of windows or walls)
Place the barrier taking into consideration the volume of its beam and relevant dead
zone
Check if the surface of the wall is free or with any obstacles (columns, drainpipes,
gutters, window sills or else)
Check on vegetation along the whole segment
We recommend to contact CIAS SERVICE. We’ll be glad to provide you all required
support and the relevant guide for wall installation.