CIAS Elettronica S.r.l.
Ed. 1.5
Installation Handbook
page
62
of
66
CORAL-PLUS
The
Response
of the barrier is set during manufacture to
”5” (default)
set on switch
SW6.
This setting is optimum for most situations
.
To obtain a different response adjust
SW6
for the required response, based on the following table:
RESPONSE MODIFICATION
SW6
Setting
Response
0
Very High Decrease of Sensitivity
Use this for targets that are very big
or very
close
to the
Tx and Rx heads.
(Big birds, cats that can jump close to the heads etc.)
1
High Decrease of Sensitivity
T
argets that are big or very
close
to the heads
Tx
and
Rx
2
Medium Decrease of Sensibility
Targets that are big
or very
close
to the heads
Tx
and
Rx
3
Decrease of Sensitivity
Targets that are big or very near to the heads Tx
and
Rx
4
Decrease of Sensitivity
Equal for every target
5
Standard
6
Increase of Sensitivity
Equal for every target
7
Increase of Sensitivity
for small target
(crawling/rolling intruder)
8
Medium increase of sensitivity
for small targets
9
High increase of Sensitivity
for small targets
5. Turn the function switch
SW1 to position 4
, and the barrier will return to normal operation.
The normal operation is also restored when the radome is closed, independent of the
position of
SW1
.
Pushing
S1
push button, will give an audible indication related to the quality of the
alignment, as described in point ”j” and activates the
Walk Test
function.
The barrier will operate with the parameters set using the software or using the
Sensitivity
SW5
and
Response SW6
switches and every variation in the microwave signal in the
sensitive zone will activate the buzzer found on the receiver board.
The buzzer sounds intermittently, the frequency of which is dependent on the intensity of the
disturbance signal, and if the frequency increases it means that the disturbance has
increased (which indicates a deeper penetration into the protected area).
If the disturbing signal is sufficient to generate an alarm condition the buzzer will give a
continuous tone. In this way it is possible to evaluate the real consistency of the sensitive
zone and also to check if there are any sources of interference present (badly fixed fences,
etc.), affecting the protection. If the walk test results do not satisfy the protection
requirements of the zone, adjust the sensitivity of the CORAL-PLUS barrier as shown in
point “k”).