12-10 CIRCULATION PUMP DEFECT
Open the Front upper cover to check the circulation
pump located at the bottom right.
- Voltage check: AC220V/60Hz
* Empty the cold tank before detaching the
circulation pump from the body.
- Detach Inlet Sol V/V
- Drain all cold water by dispensing it.
- Detach EPS
- Detach the Circulation pump by rotating it 90°
clockwise.
* Voltage is applied and not rotating, replace the
Circulation pump.
Check leakage around pump head rubber.
(Check rubber ring of the circulation pump.)
Circulation pump defect.
Check if any foreign object inside the circulation
pump.
Check leak/noise/voltage of the Circulation pump.