Inlet Sol V/V and/or Cold level Sensor Defect
(Defect if over 5 minutes total for 3 consecutive
times)
12-5 INLET SOL V/V DEFECT
Faulty inlet solenoid Valve causes water dispensing malfunction due to not supplying water to the
cold water tank.
3
Check inlet solenoid valves located at the bottm
of Controller PCB.
- Check its voltage is DC24V supplies to Sol V/V at
terminal when dispensing.
- Check if there is leak at the Sol V/V.
- Check wire connections.
> If not, replace
Sol V/V
1
2