Status
State Value
Description
Power.Standby
Lasers will start getting ready to turn on
when the lasers have cooled down
sufficiently.
Power.Halt
A critical hardware issue exists. The
laser subsystem remains off until the
issue is resolved and the system s AC
power cycled.
105 CSB DAC Calibration
OK
The color sensor board (CSBD) DAC
calibration exists.
107 LiteLOC Sensor to
Screen Calibration
OK
LiteLOC sensor-to-screen calibration
exists.
Achieve additional
performance by performing
Sensor to Screen calibration
LiteLOC sensor-to-screen calibration
does not exist.
108 LiteLOC LOS to Sensor
Calibration
OK
LiteLOC LOS-to-screen calibration exists.
109 LaserCrossPlugDetect
OK
Lasers are wired correctly.
<description of failure>
Lasers are wired incorrectly and cannot
power on.
110 Laser Reds
<value>
Displays the health status of the red
lasers.
111 Laser Greens
<value>
Displays the health status of the green
lasers.
112 Laser Blues
<value>
Displays the health status of the blue
lasers.
113 Laser Tecs
<value>
Displays the health status of the TECs.
114 Laser Cold Plate Temp
<value>°C
Displays the temperature inside the LOS.
<value>°C
Temperature exceeds the warning
threshold.
115 Laser LOS Temp
<value>°C
Displays the temperature inside LOS.
<value>°C
Temperature exceeds the warning
threshold.
116 Laser LOS Humidity
<RH value> %
Displays the humidity in the LOS.
<RH value> %
Humidity exceeds the warning threshold.