Status
State Value
Description
Unknown
Cannot determine the formatter status
due to an upstream issue.
Power Bad
The formatter detected an unexpected
power glitch and has started the process
of parking the DMD. This is often
recoverable.
Detection Fault
Cannot read the formatter hardware.
Initialization Fault
Cannot properly initialize the formatter.
Runtime Fault
The formatter experienced an
unrecoverable failure during runtime.
58
Shutter
OK
Detected the shutter and it is operating
properly.
Unknown
Cannot determine the status of the
device.
Failed
Failed to detect limit switches. Cannot
detect shutter status. While the power is
on, this is a warning state.
Failed
Failed to detect limit switches. Cannot
detect shutter status. When the power
state is off, an error state prevents
power up.
96
Power Supply Output Current
<value>A
Displays the output current from the
power supply. This value depends on the
current drawn from the supply and is
informational only.
100 Rotating Diffuser
<value> RPM
The diffuser is spinning at more than
500 RPM.
Off
The diffuser is off.
Unknown
Displayed if the housekeeping board is
not yet initialized.
<value> RPM - Low
RPM
The diffuser is spinning less than 500
RPM but more than 100 RPM.
Failed
The diffuser is spinning at less than 100
RPM.
144 Photon Module
OK
The module is working properly.
Unknown
Displayed if the housekeeping board is
not yet initialized.
Christie status system
Christie Technical Reference–Status System
9