122
LW502/LWU502 User's Manual - Operating Guide
020-001057-01 Rev. 1 (06-2016)
Troubleshooting
Issue
Cases not involving a machine defect
Reference
page
No image is
displayed via
HDBaseT.
Check the LAN cable if it is CAT5e certified or higher.
–
Try to change the LAN cable.
–
If the LAN cable is connected with more than three
extension connectors, the transmission of 100 meters
may fail.
–
Check if the extension connector is compatible with
CAT5e.
All LAN cable and extension connector connected with
HDBaseT
port must be CAT5e certified.
–
NETWORK
BRIDGE
function does
not work.
The NETWORK BRIDGE function is turned off.
Select NETWORK BRIDGE for COMMUNICATION TYPE
item in the OPTION - SERVICE - COMMUNICATION
menu.
90
Schedule
function does
not work.
The POWER SAVE function is working.
Select NORMAL for STANDBY MODE item in the
SETUP menu.
72
T
he internal clock has been reset.
Once you turn off the projector in the POWER SAVE
mode or the AC power, the current date and time setting
is reset.
Check the SCHEDULE setting for WIRELESS SETUP or
WIRED SETUP in the NETWORK menu.
–
STANDBY
OUTPUT
(AUDIO OUT,
HDMI OUT,
MONITOR OUT)
does not work
with standby
mode.
Check if POWER SAVE is set in SETUP - STANDBY
MODE.
Set NORMAL in the menu above.
If the signal is not output yet, check if a desirable item is
set in SETUP - STANDBY OUTPUT.
72
(continued on next page)
Issues that may be easy to be mistaken for machine defects (continued)