When using the remote to do electronic convergence, the following functionality is not available:
•
Lens movement functions
•
Image optimization and setting the aspect ratio
•
Keystone adjustments
•
Customized actions
•
Context-sensitive help
•
On-screen display menu
Follow these steps to adjust convergence electronically with the remote.
1. Before adjusting DMD convergence, ensure the projector has reached a steady operational
state. If switching from a white or bright test pattern to a dark convergence test pattern, or if
warming up the projector after a shutdown, allow 15 minutes for stabilization so the optics can
reach a steady state.
2. On the remote, press Test Pattern and select the E-Convergence test pattern.
The E-Convergence test pattern is displayed, including the instructional text. To remove clutter
from the screen or if you are familiar with the electronic convergence, turn off the instructional
text. On the remote, press OSD Hide for two seconds.
Until electronic convergence is completed, the displayed image may appear to be blurred and
difficult to read, especially for white text, due to the mis-convergence of the red, green, and
blue pixels.
3. Select the corner sprite you want to adjust first.
By default the top-left position is selected.